14
www.myhtec.com
CAUTION
Risk of fi re due to electrical overload
Any operation beyond the electrical specifi cations will lead to
excessive overheating of the
electrolyzer
. This may cause a fire.
Never operate the
electrolyzer
beyond the electrical specifi cations
stated in the technical data.
CAUTION
Risk of damage due to electrical overload
Any operation beyond the electrical specifications will lead to
irreparable damage to the
electrolyzer
.
Never operate the
electrolyzer
beyond the electrical specifi cations
stated in the technical data.
CAUTION
Risk of damage due to insuf
fi
cient distance to lamps
The solar module may become excessively hot or sustain irreparable
damage if it is too close to the lamp.
Observe the minimum distance defi ned by the manufacturer when
operating solar modules with lamps.
CAUTION
Risk of damage due to improper handling
Operating the
electrolyzer
using water with an electrical conductivity
of
≥
2 µS/cm will cause irreparable damage to the
electrolyzer
.
Only
fi ll the
electrolyzer
using distilled water with an electrical
conductivity of < 2 µS/cm.
NOTE
Water in the fuel cell
Ensure that there is no water in the tube of the fi lling station. Remove
any water in the tube by briefl y opening the tube clamp or the shut-
off valve, if and as needed.
If water enters the fuel cell by way of the tube, a fi lm of water on
the electrode surface may suppress the reaction of hydrogen and
oxygen within the fuel cell. In such cases, the output of the fuel cell
will be inadequate.