background image

7

Mit  der  Wiederverwendung,  der  stoff

-

lichen  Verwertung  oder  anderen  Form 

der Verwertung von Altgeräten leisten Sie 

einen wichtigen Beitrag zum Schutze un-
serer Umwelt.

Lead battery charger with diagnos-
tic function

With newest charging technology

One the most modern and most intelligent 
battery charging, diagnostic and test de-

vices for all 2V, 6 V and 12V lead batteries, 

as well as maintenance-free gel batteries 
and lead acid batteries. This battery char-
ger operates with the most modern cha-
racteristic-controlled charging technology 
and  thus  ensures  ideal  charging  condi-
tions and maintenance of lead batteries. 
Intelligent  software  constantly  monitors 
all  functions  and  controls  the  correct 
charging  procedure  depending  upon  the 

respective state. The battery can remain 
connected  for  months.  Overcharging  is 

not possible.

Five LEDs constantly indicate the opera

-

ting  status.  This  automatic  charger  can 
remain  connected  to  the  battery  during 
the winter.

Special features: 
•  Multi-stage  I/U  charging  characteristic 

I-phase, U1-phase, U2-phase 

•  Electronic  protective  circuit  protects 

against  reverse  polarity  and  short-cir

-

cuit   

• Automatic  battery  maintenance  mode 

(Automatic refreshing of the battery after 
charging)

• Trickle charging
•  Software  controlled  diagnosis  of  the 

battery  before  beginning  the  charging 

procedure, battery test function, defect 

identification

•  For 2V, 6 V and 2 V lead batteries (Acid, 

gel, AGM) 

• Charging current max. 0.6 A (automatic 
adaptation)
• 5 LED status displays: Mains, charging, 

refresh, finished, error.

Technical data:

 Input voltage: 220-240V/

AC, max. charging current 600 mA (2V), 
300mA  (2V/6V),  electronic  protection 
against short-circuits and incorrect pola-

rity,  overcharging  protection,  dimensions 

approx. 95x70x55mm

Order No. 

 

Please  read  the  operating  instruc-
tions before start-up!

Table of contents:

. Intended use 
2. Warning notes
3. Dangers
4. Safety
5. Connection and start-up
6.  Brief explanation for experienced users 

(Quick introduction)

7.  Detailed functional description (Opera-

tion method of the device)

8. Notes
9. Technical data

1. Intended use

The  intended  use  of  the  battery  charger 
encompasses  charging  and  charge  re-
tention of maintenance-free gel batteries, 

microflies  and  acid  batteries,  which  are 
suitable for the voltage and charging cur

-

rent  indicated  in  the  technical  data.  Any 
other use is not considered as intended. 

Summary of Contents for AL 600plus

Page 1: ...Mehrstufen I U Ladekennlinie I Phase U1 Phase U2 Phase Verpolungs und kurzschlusssicher durch elektronischen Schutzschaltung Automatischer Batteriepflegemodus Automatisches Refreshing der Batterie nac...

Page 2: ...r t nicht direktern Sonnenlicht Starker Staubentwicklung mechanischen Vibrati onen oder St en aus Betreiben Sie das Ger t nicht in der N he von brennbaren oder leicht entz ndlichen Materialien Le gen...

Page 3: ...dem Laden von nicht war tungsfreien Bleiakkus den S urestand Pr fen Sie bei l ngerer Ladedauer von nicht wartungsfreien Bleiakkus zwischen durch den S urestand Kontrollieren Sie aus Sicherheitsgr nden...

Page 4: ...emmen Sollte das Ladeger t nach l ngerer Ladezeit nicht Fertig oder Voll anzeigen so kann es sein dass die Batterie einen Leckstrom aufweist oder an der Batterie ist noch ein Verbraucher angeschlossen...

Page 5: ...atterie und ca 0 3A f r 2V und 6V Batterie U1 Phase Hauptladephase mit kon stanter Spannung von 14 3 V bzw 2 4V oder 7 15V U2 Phase Ladeerhaltung mit kon stanter Spannung von 13 8 V bzw 2 4V oder 7 15...

Page 6: ...g liche Ursache Ladeger t oder Batterie defekt 11 Hinweise Hinweis N1 Eine tiefentladene 12V Batte rie wird grunds tzlich mit einem Strom bis max 0 3A geladen Hinweis N2 Dauert ein Refreshvorgang weni...

Page 7: ...cuit protects against reverse polarity and short cir cuit Automatic battery maintenance mode Automatic refreshing of the battery after charging Trickle charging Software controlled diagnosis of the ba...

Page 8: ...as well as wetness The device may only be used in dry and closed rooms Switch the device off immediately and sa feguard it against unintentional operation if it must be assumed that safe operation is...

Page 9: ...D lights up Set battery voltage Set the slide switch to 2V 6 V and or 12V depending on the battery you want to charge Connecting to the battery Connect the red connecting terminal of the battery charg...

Page 10: ...voltage of the loaded battery thereby drops back to the rated voltage The battery charger evalu ates the battery as defective if the test is not passed the device then switches itself off and the Err...

Page 11: ...ut must be brought to a collection point for recycling electrical and electro nic devices This is pointed out by the symbol on the product in the operating instructions or on the packing Materials of...

Page 12: ...sion et au courant de charge indiqu s dans les caract ristiques techniques Toute autre utilisation non conforme est interdite Seul l utilisateur sera tenu pour responsa ble en cas de dommages r sultan...

Page 13: ...des accus au plomb avec entretien en cas de chargement trop long Contr ler r gu li rement le d roulement du chargement par mesure de s curit Eviter principalement des feux de plein air les bougies et...

Page 14: ...avec de l eau distill e Respecter les indications du fabricant de batterie 7 Description d taill e des fonctions pour le chargement Apr s le branchement sur le secteur 230V 50Hz le LED secteur s allu...

Page 15: ...e se synchronise de sorte que la tension de la batterie commute directement sur 13 8 6 9 2 3 V Apr s 15 minutes le pro gramme R initialiser red marre Ceci se r p te de mani re cyclique jusqu ce que le...

Page 16: ...ding en onderhoud van de loodaccu Een intelligente software con troleert continu de volledige functies en stuurt afhankelijk van de status de juiste laadprocedure De accu kan maanden lang aangesloten...

Page 17: ...a gebruik altijd op isolatiegebreken of breuk worden gecontroleerd Bij het vast stellen van een fout in de toevoer moet het apparaat direct buiten gebruik wor den genomen Het apparaat mag alleen op ee...

Page 18: ...lgens de zwarte klem op de minpool van de accu At tentie Nooit aansluitingen op de voertu igcarrosserie klemmen Het laadapparaat functioneert bij een omgevingstemperatuur van 25 C 45 C Bij welke tempe...

Page 19: ...de spanning constant gehouden U1 Phase en past de laad stroom zich aan de laadstand van de accu aan Des te voller de accu des te geringer de laadstroom Als een laadstroom onder ca 100 mA blijft zie Op...

Page 20: ...u een aangesloten last heeft bijv boordelektronica die meer dan 100mA verbruikt wordt een laadsluitbepaling no oit bereikt en blijft het laadapparaat op eeuwig in de laadmodus staan 12 Technische gege...