WINTER TIMBERMAX 4 – 23 ECO
42
11.3
Troubles and trouble-shooting methods of electric power
TABLE 11
No.
Troubles
Possible causes
Trouble-shooting method
1
Machine can not be
started
No power supplied or low voltage
Check
the
fuse,
“Emergency stop” button
and breaker
2
The motor for
cutter-shaft can not
be started or continuous
feed can not be
operated
a)
“Emergency stop” button has
been pressed down
b)
The cover is opened
c)
The min. breaker on the
control transformer is
overheated broken
d)
Air-switch of the motor is cut
off
e)
Supply of air is not deficient
f)
Limit switch at feed entrance is
pressed down or connect badly
g)
Locking limit switch on the
safeguard connect badly
a)
Restore the
“Emergency stop” button
b)
Close the cover.
c)
Switch on the min.
breaker
d)
Turn on the air-switch
e)
Recover the supply of
air
f)
Reset or change limit
switch
g)
Check locking limit
switch