External Fault Indication
making the signal suitable for directly driving and external LED. Alternatively, the signal
may be buffered and used as a status indicator for the connection to external control
circuitry.
Amplifier Enable Inputs
The amplifier is provided with two inputs which must receive the proper signals
before the
amplifier will become enabled
. In the disabled state, the output of the amplifier goes into a
high impedance state. The inputs, /ENABLE and ENABLE are ANDed together to
determine the logical state. Table below shows the truth table for these connections.
ENABLE
/ENABLE
Amplifier Status
0V
0V
Disabled
0V
5V
Disabled
5V
5V
Disabled
5V
0V
ENABLED
Table 10. Amplifier enable truth table.
The /ENABLE input is tied to +5V through a 4.99k ohm resistor. The ENABLE input is
tied to GND (0V) through a 1k ohm resistor. This default configuration leaves the amplifier
in a normally disabled state.
Both the ENABLE and the /ENABLE inputs have specific thresholds that must met in order
for the amplifier to be enabled for operation.
Signal
Threshold
Minimum
Maximum
ENABLE
> 2.4V
0V
5V
/ENABLE
< 0.8V
0V
5V
Power Amplifier Module User's Guide
31