8
•
Labels for the fiber that connects two devices
Table 2 Information on labels affixed to the fiber between two devices
Content
Meaning
Example
MN-B-C-D-R/T
MN
—Rack number
•
M
—Row number of the rack in the
equipment room, in the range of A to Z.
•
N
—Column number of the rack in the
equipment room, in the range of 01 to 99.
For example, A01.
B
—Chassis number
Numbered in top-down order with two digits,
for example, 01
C
—Slot number
Numbered in top-down and left-right order
with two digits, for example, 01.
D
—Fiber port number
Numbered in top-down and left-right order
with two digits, for example, 05.
R
—Optical receiving interface
T
—Optical transmitting
interface
N/A
MN-B-C-D-R/T
MN
—Rack number
The meanings are the same as above. If the
local device and the peer device are not in the
same equipment room, MN can be the name
of the equipment room.
B
—Chassis number
C
—Slot number
D
—Fiber port number
R
—Optical receiving interface
T
—Optical transmitting
interface
N/A
•
Labels for the fiber that connects the device and the ODF
Table 3 Information on labels affixed to the fiber between the device and the ODF
Content
Meaning
Example
MN-B-C-D-R/T
MN
—Rack number
•
M
—Row number of the rack in the
equipment room, in the range of A to Z.
•
N
—Column number of the rack in the
equipment room, in the range of 01 to 99.
For example, A01.
B
—Chassis number
Numbered in bottom-up order with two digits,
for example, 01.
C
—Slot number
Numbered in top-down and left-right order
with two digits, for example, 01.
D
—Fiber port number
Numbered in top-down and left-right order
with two digits, for example, 05.
R
—Optical receiving interface
T
—Optical transmitting
interface
N/A
ODF-MN-B-C-R/T
MN
—Row number and column
number of ODF
•
M
—Row number of the rack in the
equipment room, in the range of A to Z.
•
N
—Column number of the rack in the
equipment room, in the range of 01 to 99.
Summary of Contents for CR16000-F
Page 40: ...9 Figure 11 Securing the power cord method one Figure 12 Securing the power cord method two...
Page 47: ...16 Figure 22 Installing an SMB coaxial clock cable...
Page 66: ...5 Figure 5 Removing a common card Figure 6 Removing a card with a locking clip 1 3 2...
Page 76: ...15 Figure 19 Replacing an SMB coaxial clock cable...
Page 89: ...12 Figure 14 Example of a device label...