5-38
Field
Description
Warning-UpperLimit
Warning-level high temperature alarm threshold.
Alarm-UpperLimit
Alarm-level high temperature alarm threshold.
Shutdown-Upperlimit
Shutdown-level high temperature alarm threshold. The firewall automatically
powers off when the temperature exceeds this threshold.
NOTE:
Only the F1000-AI-20, F1000-AI-30, F1000-AI-50, F1000-AI-60, F1000-AI-70, F1000-AI-80, and
F1000-AI-90 firewalls support the
display
environment
command.
Displaying the operational statistics about the
firewall
When you perform routine maintenance or the system fails, you might need to view the operational
information of each functional module for locating failures. Typically you need to run
display
commands one by one. To collect more information one time, you can execute the
display
diagnostic-information
command in any view to display or save the operational statistics of
multiple functional modules of the firewall.
•
Save the operational statistics of each functional module of the firewall:
<Sysname> display diagnostic-information
Save or display diagnostic information (Y=save, N=display)? [Y/N]:y
Please input the file name(*.gz)[flash:/diag.gz]:
Diagnostic information is outputting to flash:/diag.gz.
Please wait...
Save successfully.
To view the diag.gz file:
a.
Execute the
gunzip
diag.gz
command in user view to decompress the file.
b.
Execute the
more diag
command.
c.
Press
Pg Up
and
Pg Down
.
•
Display the operational statistics for each functional module of the firewall:
<Sysname> display diagnostic-information
<Sysname>display diagnostic-information
Save or display diagnostic information (Y=save, N=display)? [Y/N]:n
===============================================
===============display cpu===============
Slot 1 CPU 0 CPU usage:
13% in last 5 seconds
13% in last 1 minute
13% in last 5 minutes
...