Command Manual – System Maintaining and Debugging
H3C S7500E Series Ethernet Switches
Chapter 1 Basic Configuration Commands
1-14
Description
Use the
display version
command to view system version information.
By viewing system version information, you can learn about the current software
version, rack type and the information related to the main control board and interface
boards.
Examples
# Display system version information.
<Sysname> display version
H3C Comware Platform Software
Comware Software, Version 5.00, Release 0000
Copyright (c) 2004-2007 Hangzhou H3C Tech. Co., Ltd. All rights reserved.
S7502E uptime is 0 week, 0 day, 21 hours, 43 minutes
Slot 0 Without Board
SRPG(M) 1:
Uptime is 0 weeks,0 days,21 hours,43 minutes
S7502E SRPG(M) with 1 BCM1125H Processor
DRAM: 512M bytes
FLASH: 64M bytes
NVRAM: 512K bytes
Hardware Version: VER.A
Bootrom Version: 108
CPLD Version: 002
Release Version: S7502E-0000
LPU 2:
Uptime is 0 weeks,0 days,21 hours,42 minutes
S7502E LPU with 1 BCM1122H Processor
DRAM: 256M bytes
FLASH: 0M bytes
NVRAM: 0K bytes
Hardware Version: VER.C
Bootrom Version: 107
CPLD Version: 004
Release Version: S7502E-0000
Slot 3 Without Board
1.1.14 header
Syntax
header
{
incoming | legal
|
login | motd
|
shell
}
text