Command Manual – System Maintaining and Debugging
H3C S7500E Series Ethernet Switches
Chapter 2 System Maintaining and
Debugging Commands
2-6
View
Any view
Parameters
-f first-ttl
: Specifies the first TTL, that is, the allowed number of hops for the first packet,
in the range 1 to 255. It defaults to 1 and must be less than the maximum TTL.
-m max-ttl
: Specifies the maximum TTL, that is, the maximum allowed number of hops
for a packet, in the range 1 to 255. It defaults to 30 and must be greater than the first
TTL.
-p port
: Specifies the UDP port number of the destination device, in the range 1 to
65535. The default value is 33434. It is unnecessary to modify this parameter.
-q
packet-number
: Specifies the number of probe packets sent each time, in the range
1 to 65535, defaulting to 3.
-w timeout
: Specifies the timeout time of the probe packets, in the range 1 to 65535, in
milliseconds. The default value is 5000 ms.
remote-system
: IPv6 address or host name (a string of 1 to 46 characters) of the
destination device.
Description
Use the
tracert
ipv6
command to view the routers the IPv6 packets traverse from the
source to the destination device.
Examples
# View the routes involved for packets to travel from the source to the destination with
IPv6 address 3002::1.
<Sysname> tracert ipv6 3002::1
traceroute to 3002::1 30 hops max,60 bytes packet
1 3003::1 30 ms 10 ms 10 ms
2 3002::1 10 ms 11 ms 9 ms
2.2 System Debugging Commands
2.2.1 debugging
Syntax
debugging
{
all
[
timeout
time
] |
module-name
[
option
] }
undo
debugging
{
all
|
module-name
[
option
] }
View
User view