Installation Manual
H3C SecPath F1000-A Firewall
Chapter 1 Product Overview
1-3
Item
Description
Physical dimensions
(H
×
W
×
D)
44
×
436
×
430 mm (1.7
×
17.2
×
16.9 in.), excluding the
rubber feet
AC+AC
Rated voltage range: 100 VAC to 240 VAC, 50 Hz or 60
Hz
Max voltage range: 90 VAC to 264 VAC, 50 Hz or 60 Hz
Rated current: 1.5 A
Input
power
DC+DC
Rated voltage range: – 60 VDC to –48 VDC
Max voltage range: – 72 VDC to –36 VDC
Rated current: 1.5 A
Max power
consumption
100 W
Operating temperature 0
°
C to 40
°
C (32
°
F to 104
°
F
)
Operating humidity
(non-condensing)
10% to 90%
Note:
Double data rate synchronous dynamic random access memory (DDR DSRAM) stores
the communication data with the CPU and running system.
Flash memory stores application files, exceptional information and configuration files.
Boot read only memory (Boot ROM) stores the bootstrap program files.
1.2.3 LEDs
The following table describes the LEDs on the front panel of the H3C SecPath F1000-A
and describes how to read their status.
Table 1-2
LEDs on the front panel of the H3C SecPath F1000-A
LED
Description
PWR0
Power supply unit (PSU) LED:
OFF means the PWR0 is not supplying power to the device; ON
means the PWR0 is supplying power to the device.
PWR1
PSU LED:
OFF means the PWR1 is not supplying power to the device; ON
means the PWR1 is supplying power to the device.
SYS
System operating status LED:
On means the system is operating normally; OFF means the
system is operating abnormally.