NOTE: 

The three-position DIP switch can shift the switch functions as 
follows: 

 

标准交换

—Enable flow control and downshift. 

 

网络克隆

—Disable flow control and enable downshift. 

 

汇聚上联

—Enable flow control, downshift, and uplink port 

aggregation. (Ports 15 and 16 on the S16G-U and ports 23 
and 24 on the S24G-U are uplink ports.) 

 

Rear panel 

Figure 12 S8G-U rear panel 

 

 

Figure 13 S9-PWR rear panel 

 

 

Summary of Contents for Mini Series

Page 1: ...ironment Prevent water or moisture from entering the chassis Place the switch in a clean environment Dust buildup on the chassis might result in electrostatic adsorption which reduces lifespan of the...

Page 2: ...unting Workbench mounting Wall mounting S8G U Not supported Supported Supported S9 PWR Not supported Supported Supported S16G U Supported Supported Not supported S24 U Supported Supported Not supporte...

Page 3: ...the switch on a rack shelf in the rack Push the switch in until the oval holes in the brackets align with the mounting holes in the front rack posts 4 Use screws to secure the mounting brackets to th...

Page 4: ...p and clean the four recessed areas in the chassis bottom with a soft and dry cloth 3 Attach the rubber feet to the recessed areas 4 Place the switch upside up on the workbench Mounting on a wall You...

Page 5: ...or If you use screws and screw anchors of the recommended size the hole diameter is 5 mm 0 20 in 2 Drill two holes spacing 90 mm 3 54 in on the wall Make sure the two holes are on a horizontal line 3...

Page 6: ...n a wall Connecting cables Connecting the grounding cable CAUTION Correctly connecting the grounding cable is crucial to lightning protection and EMI protection The switch is not provided with a groun...

Page 7: ...at the other end of the cable 3 Remove the hex nut from a grounding post on the grounding strip Attach the loop to the grounding post and fasten the hex nut Figure 5 Connecting the grounding cable Co...

Page 8: ...nnect the power adapter 1 Connect the power cord to the power adapter This step is not required for an S8G U switch 2 Connect the DC connector of the power adapter to the DC power receptacle on the sw...

Page 9: ...9 Appendix A Chassis views and technical specifications Chassis views Front panel Figure 7 S8G U front panel Figure 8 S9 PWR front panel Figure 9 S16G U front panel...

Page 10: ...front panel 1 Power LED Power 2 10 100 1000Base T copper port status LED 3 Uplink port status LED 4 10 100Base TX copper port status LED 5 PoE status LED 6 PoE MAX LED 7 10 100 1000Base T copper port...

Page 11: ...Enable flow control and downshift Disable flow control and enable downshift Enable flow control downshift and uplink port aggregation Ports 15 and 16 on the S16G U and ports 23 and 24 on the S24G U ar...

Page 12: ...ower receptacle Technical specifications Table 2 Technical specifications 1 Item S8G U S9 PWR S16G U Dimensions H W D 27 158 105 mm 1 06 6 22 4 13 in 27 235 105 mm 1 06 9 25 4 13 in 44 330 173 mm 1 73...

Page 13: ...7 8 W Power consumption full configuration 4 W 70 W 11 W Cooling system Natural cooling Input voltage DC 12 V 0 5 A DC 54 V 1 48 A AC 100 VAC to 240 VAC 50 Hz or 60 Hz Port specifications RJ 45 connec...

Page 14: ...n Weight 1 5 kg 3 31 lb 1 6 kg 3 53 lb Port 24 10 100Base TX copper port 24 10 100 1000Base T copper port PoE power supply Not supported Not supported Power consumption static 3 7 W 7 8 W Power consum...

Page 15: ...e GB4943 1 Appendix B LEDs LED Status Description Power LED power Steady green The switch is powered on and the power module is operating correctly Off The switch is not powered on or the power module...

Page 16: ...ng green The port is receiving or sending data at 1000 Mbps Steady yellow A 10 100 Mbps link is present Flashing yellow The port is receiving or sending data at 10 100 Mbps Off No link is present PoE...