40
Troubleshooting
IMPORTANT:
•
The barcode on the router chassis contains product information that must be provided to local sales
agent when you return a faulty router for service.
•
Keep the tamper-proof seal on a mounting screw on the chassis cover intact, and if you want to open the
chassis, contact H3C for permission. Otherwise, H3C shall not be liable for any consequence.
Power supply system failure
Symptom
The router cannot be powered on. The power LED on the front panel is off.
Solution
To resolve the problem:
1.
Turn off the power switch.
2.
Verify that the power cord of the router is correctly connected to the router and the power source.
3.
Verify that the power source is operating correctly.
4.
Verify that the power cord is in good condition.
5.
If the problem persists, contact H3C Support.
Fan failure
Symptom
After the router starts up, the following error message appears on the configuration terminal:
%Jun 22 16:11:37:485 2010 H3C DEV/4/FAN FAILED:
Fan 1 failed.
Solution
To resolve the problem:
1.
Verify that the fans are correctly installed.
2.
Verify that no obstacle enters the chassis and blocks the fans.
3.
Verify that no fan stops rotating. If a fan stops rotating, replace the fan.
4.
If the problem persists, power off the router and contact H3C Support.
Summary of Contents for MSR 26-00-10
Page 16: ...9 Figure 2 Installation flow ...