122
garp timer join
Use
garp timer join
to set the GARP Join timer for an Ethernet port, Layer-2 aggregate interface, or
all ports in a port group.
Use
undo garp timer join
to restore the default of the GARP Join timer. This might fail if the default
is beyond the valid value range for the Join timer.
Syntax
garp timer join timer-value
undo garp timer join
Default
The Join timer is set to 20 centiseconds.
Views
Ethernet interface view, Layer-2 aggregate interface view, port group view
Default command level
2: System level
Parameters
timer-value
: Specifies the Join timer (in centiseconds), which must be a multiple of 5 and range from
twice the Hold timer (inclusive) and half the Leave timer (inclusive).
Usage guidelines
The following matrix shows the command and hardware compatibility:
Hardware Command
compatibility
MSR800 No
MSR 900
No
MSR900-E No
MSR 930
No
MSR 20-1X
No
MSR 20
No
MSR 30
Yes
MSR 50
Yes
MSR 2600
Yes
MSR3600-51F Yes
Examples
# Set the GARP Join timer to 25 centiseconds, assuming that both the Hold timer and the Leave
timer are using the default.
<Sysname> system-view
[Sysname] interface ethernet 1/1
[Sysname-Ethernet1/1] garp timer join 25
Related commands
•
display garp timer
•
garp timer hold