background image

Feature 

特点

 

Description 

说明

 

Self-protection 

具有保护功能

 

Provide input undervoltage, output overvoltage, short-circuit, output overcurrent, 
and overtemperature protections. 

具有输出输入欠压保护、输出过压保护、短路保护、输出限流保护、过温保护
等功能

 

Redundancy 

支持冗余备份

 

Multiple power supplies can be connected in parallel to achieve redundancy 
and load sharing.  

支持多电源模块并联工作,从而可以实现受电设备电源系统的冗余备份,并且
备份电源间具有负载均流功能

 

Hot swappable 

支持热插拔

 

You can remove one of power supplies in 1+1 redundancy while the device is 
operating. Before removing the power supply, disconnect the power supply 
from the external power supply system. 

在设备不断电的情况下,可先断开

1+1

冗余备份电源系统中某个电源模块与外

置供电系统的连接,然后直接对电源模块进行插拔操作

 

 

 

A power supply shuts down after an input undervoltage, short circuit, output 
overcurrent, or overtemperature condition occurs. After the issues are 
resolved, it automatically restores power supply. 

当电源模块触发输入欠压保护、短路保护、输出限流保护、过温保护功能时,
电源停止供电。当故障消失后,会自动恢复供电。

 

A power supply shuts down and is locked after an output overvoltage 
condition occurs. It cannot restore power supply automatically after the 
issue is resolved. To restore power supply, perform the following tasks: 

当电源模块触发输出过压保护功能时,电源锁死,停止供电。当电源模块被
锁死时,其不能自动恢复正常工作,可以采用以下步骤来使电源模块恢复正
常工作:

 

 

Disconnect the power cord from the external power supply system. 

首先断开电源线与外置电源系统的连接;

 

 

Disconnect the power cord from the power supply and then reconnect it. 

接着将电源线插头从电源模块上拔出,然后重新连接电源线至电源模块;

 

 

Connect the power cord to the external power supply system. 

最后连接电源线至外置电源系统。

 

Technical specifications 

电源模块规格

 

Item 

项目

 

Specifications 

规格

 

AC input 

交流输入

 

Rated input voltage range 

额定输入电压范围

 

100 to 240 VAC @ 50/60 Hz 

Max input voltage range 

最大输入电压范围

 

90 to 290 VAC @ 47 to 63 Hz 

Max input current 

最大输入电流

 

13 A 

Summary of Contents for PSR1600-54A-B

Page 1: ...power supply is applicable to multiple switch models The applicable switch models might change over time For compatibility of the power supply with switch models contact the marketing personnel or tec...

Page 2: ...circuit output overcurrent or overtemperature condition occurs After the issues are resolved it automatically restores power supply A power supply shuts down and is locked after an output overvoltage...

Page 3: ...176 to 290 VAC 47 to 63 Hz DC 1600 W Dimensions H W D 40 2 73 5 185 mm 1 58 2 89 7 28 in Weight 1 kg 2 20 lb Operating temperature 10 C to 55 C 14 F to 131 F Relative humidity 5 RH to 95 RH noncondens...

Page 4: ...e power supply make sure the operating voltage of the external power supply system is as required by the power supply and the output voltage of the power supply is as required by the powered device To...

Page 5: ...upply gently If you insert the power supply upside down you will encounter a hard resistance because of the special structure designs of the slot and power supply You need to pull out the power supply...

Page 6: ...rasp the handle of the power supply with one hand and support its bottom with the other and slide the power supply slowly along the guide rails into the slot Make sure the latch on the power supply cl...

Page 7: ...ke sure the circuit breaker for the power feed is turned off 1 Connect the female connector of the power cord to the power input receptacle on the power supply 2 Use a cable tie to secure the power co...

Page 8: ...he power supply part way out of the slot 4 Grasping the handle of the power supply with one hand and supporting its bottom with the other pull the power supply slowly out of the slot along the guide r...