Enabling power supply management
•
If power supply management is not enabled when you add a new card by inserting it into the slot
or starting power supply to the card by using the
power-supply
command, the system directly
powers on the card, and the power supply may become unstable or the system may restart because
of overloading.
•
If power supply management is enabled when you add a new card by inserting it into the slot or
starting power supply to the card by using the
power-supply
command, the system compares the
maximum power consumption of the card against the available power (including the redundant
power supply). If the former is not greater than the latter, the system supplies power to the card,
otherwise, the system does not supply power to the card.
To enable power supply management:
Step Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Enable power supply
management.
•
In standalone mode:
power-supply policy enable
•
In IRF mode:
power-supply policy enable chassis
chassis-number
Enabled by default.
Configuring the number of redundant power supplies
Redundant power supplies are reserved for power supply backup and power supply threshold alarming.
With multiple redundant power supplies configured in the system, if a power supply fails or the system
power supply is overloaded, the system automatically enables a redundant power supply. As a result, the
number of redundant power supplies decreases by one.
If power supply management is disabled, the system does not reserve any redundant power supply. In
this case, you can also use the
power-supply policy redundant
command to configure the number of
redundant power supplies, and this configuration will take effect after power supply management is
enabled.
To configure the number of redundant power supplies:
Step Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Enable power supply
management.
•
In standalone mode:
power-supply policy enable
•
In IRF mode:
power-supply policy enable chassis
chassis-number
By default, power supply
management is enabled.
Summary of Contents for S12500 Series
Page 40: ...30 Figure 28 Installing an upper expansion cable management bracket 1 2 3 4 5 6 7...
Page 109: ...99 Figure 74 Replacing a card for the S12504 A Card to be removed B Card to be installed...
Page 149: ...139 Figure 85 Loopback operation on an optical transceiver...
Page 164: ...154 Figure 100 Example of a device label...