77
•
If a port is automatically shut down due to hardware failure protection, its status displayed with the
display interface
command is
Protect DOWN
. To bring up the port, use the
undo shutdown
command on the port.
•
If a card is isolated or its software is not allowed to be loaded due to hardware failure fix operations,
you can plug out the card and then plug it in to recover the card status.
•
After configuring in-service diagnosis and failure protection, you can use the
display
hardware-failure-detection
command to check the running information of the feature.
Configuration procedure
To configure in-service hardware failure diagnosis and failure protection:
Step Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Enable in-service
hardware failure
detection and
configure fix actions
taken in case of
hardware failures.
hardware-failure-detection
{
chip | board |
forwarding
} {
off | warning
| reset | isolate
}
Fix actions for hardware failures:
•
off
—Takes no action.
•
warning
—Sends warning messages.
•
reset
—Resets the failed card.
•
isolate
—Shuts down the failed port, isolates
the failed card, prohibits the failed card from
loaded, or powers off the failed card to
reduce the impact of the failure to the system.
By default, the fix action taken for all hardware
failures is
warning
.
3.
Enable hardware
failure protection for
aggregation groups.
hardware-failure-protection
aggregation
Optional.
Disabled by default.
This command is effective only when the fix
action is configured as
isolate
.
4.
Enter Ethernet interface
view.
interface
interface-type
interface-number
N/A
5.
Configure hardware
failure protection for
the port.
hardware-failure-protection
auto-down
Optional.
Disabled by default.
This command is effective only when the fix
action is configured as
isolate
.
Displaying the operating state of fans
Use the
display fan
command to display the operating state of fans on your switch.
•
In standalone mode:
# Display detailed information about all fans on the switch.
<Sysname> display fan verbose
Fan-tray 1:
Software version: 101
Hardware version: Ver.A
CPLD version: 001
Fan number: 12
Summary of Contents for S12500 Series
Page 40: ...30 Figure 28 Installing an upper expansion cable management bracket 1 2 3 4 5 6 7...
Page 109: ...99 Figure 74 Replacing a card for the S12504 A Card to be removed B Card to be installed...
Page 149: ...139 Figure 85 Loopback operation on an optical transceiver...