6-3
Replacing a module
Before you replace a module, remove all its cables. To remove the cables from a service module, you
can first remove the cable management brackets at the two sides of it.
The replacement procedure is similar for MPUs, service modules, and fabric modules. Before you
rotate outward the ejector levers of the module, perform either of the following tasks:
•
MPU or service module
—Loosen the captive screws on the module.
•
Fabric
module
—Press the buttons on the ejector levers to release them.
If you are not to install a module in a slot, install a blank filler panel in the slot to ensure adequate
ventilation and dust prevention.
Replacing an MPU or service module
1.
Prepare an antistatic mat to place the removed MPU or service module.
2.
Wear an ESD wrist strap, and make sure it makes good skin contact and is reliably grounded.
For more information, see "Installing FRUs."
3.
Use a Phillips screwdriver to loosen the captive screws on the MPU or service module, as
shown by callout 1 in
.
4.
Perform either of the following tasks:
{
For a service module, S12516R MPU, or S12508R MPU, hold the ejector levers on the
module and rotate outward the ejector levers, as shown by callout 2 in
. Then pull
the module part way out of the slot.
{
For an S12504R MPU, pivot up the handle of the MPU and pull the MPU part way out of the
slot, as shown by callout 2 in
5.
Supporting the MPU or service module bottom with the left hand, slowly pull the MPU or service
module out of the slot along the guide rails with the right hand, as shown by callout 3 in
.
6.
Place the removed MPU or service module on the antistatic mat.
7.
Install a new MPU or service module. For the MPU or service module installation procedure,