Command Manual (For Soliton) – Smart Link-Monitor Link
H3C S3100 Series Ethernet Switches
Chapter 1 Smart Link Configuration
Commands
1-3
Table 1-2
Description on the fields of the
display smart-link group
command
Field
Description
Member
Member of the Smart Link group
Role
Port role of a Smart Link group member: master or slave.
Status
Port status of a Smart Link group member when the link of this
member port is up: active or standby.
Flush-count
Number of sent flush messages
Last-flush-time
Time when the last flush message is sent. If no flush message is
sent, “NA” will be displayed.
1.1.3 flush enable control-vlan
Syntax
flush enable control-vlan vlan-id
undo flush enable
View
Smart Link group view
Parameter
vlan-id
: Control VLAN ID, in the range of 1 to 4,094.
Description
Use the
flush enable control-vlan
command to enable the function of sending flush
messages in the specified control VLAN.
Use the
undo flush enable control-vlan
command to disable the function of sending
flush messages to the specified control VLAN.
By default, no control VLAN is specified.
Example
# Configure to send flush messages within control VLAN 1.
<Sysname> system-view
System View: return to User View with Ctrl+Z.
[Sysname] smart-link group 1
[Sysname-smlk-group1] flush enable control-vlan 1