Command Manual (For Soliton) – Login
H3C S3100 Series Ethernet Switches
Chapter 1 Login Commands
1-14
Use the
undo history-command max-size
command to revert to the default history
command buffer size.
By default, the history command buffer can contain up to ten commands.
Related commands:
display history-command
.
Examples
# Set the size of the history command buffer of AUX 0 to 20 to enable it to store up to 20
commands.
<Sysname> system-view
System View: return to User View with Ctrl+Z.
[Sysname] user-interface aux 0
[Sysname-ui-aux0] history-command max-size 20
1.1.11 idle-timeout
Syntax
idle-timeout minutes
[
seconds
]
undo idle-timeout
View
User interface view
Parameters
minutes
: Number of minutes. This argument ranges from 0 to 35,791.
seconds
: Number of seconds. This argument ranges from 0 to 59.
Description
Use the
idle-timeout
command to set the timeout time. The connection to a user
interface is terminated if no operation is performed in the user interface within the
timeout time.
Use the
undo idle-timeout
command to revert to the default timeout time.
You can use the
idle-timeout
0 command to disable the timeout function.
The default timeout time is 10 minutes.
Examples
# Set the timeout time of AUX 0 to 1 minute.
<Sysname> system-view
System View: return to User View with Ctrl+Z.
[Sysname] user-interface aux 0
[Sysname-ui-aux0] idle-timeout 1