Command Manual (For Soliton) – AAA
H3C S3100 Series Ethernet Switches
Chapter 1 AAA Configuration Commands
1-66
z
For an 802.1x user, if you have specified to use EAP authentication, the switch will
encapsulate and send the contents from the client directly to the server. In this
case, the configuration of the
user-name-format
command is not effective.
Related commands:
radius scheme
.
Examples
# Specify to exclude ISP domain names from the usernames to be sent to RADIUS
server in RADIUS scheme radius1.
<Sysname> system-view
System View: return to User View with Ctrl+Z.
[Sysname] radius scheme radius1
New Radius scheme
[Sysname-radius-radius1] user-name-format without-domain
1.3 HWTACACS Configuration Commands
1.3.1 data-flow-format
Syntax
data-flow-format data
{
byte | giga-byte | kilo-byte | mega-byte
}
data-flow-format packet
{
giga-packet | kilo-packet | mega-packet | one-packet
}
undo data-flow-format
{
data | packet
}
View
HWTACACS scheme view
Parameters
data
: Sets the data unit of outgoing HWTACACS data flows, which can be byte,
giga-byte, kilo-byte, or mega-byte.
packet
: Sets the packet unit of outgoing HWTACACS data flows, which can be
one-packet, giga-packet, kilo-packet, or mega-packet.
Description
Use the
data-flow-format
command to set the units of data flows to TACACS servers.
Use the
undo data-flow-format
command to restore the default units.
By default, the data unit and packet unit for outgoing HWTACACS flows are byte and
one-packet respectively.
Note that the specified unit of data flows sent to the TACACS server must be consistent
with the traffic statistics unit of the TACACS server. Otherwise, accounting cannot be
performed correctly.