Command Manual (For Soliton) – Stack-Cluster
H3C S3100 Series Ethernet Switches
Chapter 2 HGMP V2 Configuration
Commands
2-13
Description
Use the
ntdp timer
command to configure the interval to collect topology information
periodically.
Use the
undo ntdp timer
command to restore the default interval.
By default, this interval is one minute.
After the interval is set to a non-zero value, the switch will collect topology information
periodically at this interval. You can also use the
ndp explore
command to start a
topology collection process manually.
Note that:
z
Only the management switch can collect topology periodically, and a member
switch cannot. However, you can use the
ndp explore
command on the member
switch to start a topology collection process manually.
z
After a cluster is set up, the management switch will collect the topology
information of the network at the topology collection interval you set and
automatically add the candidate switches it discovers into the cluster.
z
If you do not want the candidate switches to be automatically added into the
cluster, you can set the topology collection interval to zero, and use the
add-member
command to add the candidate switches to the cluster manually.
Examples
# Set the topology collection interval to 30 minutes.
<aaa_0.Sysname> system-view
System View: return to User View with Ctrl+Z.
[aaa_0.Sysname] ntdp timer 30
2.2.7 ntdp timer hop-delay
Syntax
ntdp timer hop-delay time
undo ntdp timer hop-delay
View
System view
Parameters
time
: Device forwarding delay in milliseconds. This argument ranges from 1 to 1,000.
Description
Use the
ntdp timer hop-delay
command to set the delay for devices to forward
topology collection requests.