Command Manual (For Soliton) – SNMP-RMON
H3C S3100 Series Ethernet Switches
Chapter 2 RMON Configuration Commands
2-1
Chapter 2 RMON Configuration Commands
2.1 RMON Configuration Commands
2.1.1 display rmon alarm
Syntax
display rmon alarm
[
entry
-
number
]
View
Any view
Parameters
entry
-
number
: Alarm entry index, in the range 1 to 65535.
Description
Use the
display rmon
alarm
command to display the configuration of a specified alarm
entry or all the alarm entries. The configuration information includes: sampling type,
sampled node, sampling interval, rising and falling thresholds that trigger alarms, the
condition under which an alarm is triggered, and the last sampled value.
Related commands:
rmon alarm
.
Examples
# Display the configuration of all the alarm entries.
<Sysname> display rmon alarm
Alarm table 1 owned by user1 is VALID.
Samples type : absolute
Variable formula : 1.3.6.1.2.1.16.1.1.1.4.1<etherStatsOctets.1>
Sampling interval : 20(sec)
Rising threshold : 100(linked with event 1)
Falling threshold : 10(linked with event 2)
When startup enables : risingOrFallingAlarm
Latest value : 5510006
Table 2-1 display rmon alarm
command output description
Field
Description
Alarm table
Index of an entry in the alarm entry
user1
Entry owner: user1