Command Manual (For Soliton) – HWPing
H3C S3100 Series Ethernet Switches
Chapter 1 HWPing Commands
1-7
Table 1-3
Description on the fields of the
display hwping history
command
Field
Description
Response
Roundtrip time in the case of a successful test,
timeout time in the case of test timeout, or 0 in the
case of a test failure (in milliseconds)
Status
Test result values, including:
1: responseReceived: Response received
2: unknown: Unknown error.
3: internalError: System internal error
4: requestTimeOut: Request timed out
5: unknownDestinationAddress: Unknown
destination address
6: noRouteToTarget: Destination unreachable
7: interfaceInactiveToTarget: Interface to destination
address inactive
8: arpFailure: ARP operation failed.
9: maxConcurrentLimitReached: Maximum limit of
concurrent accesses reached
10: unableToResolveDnsName: Unable to resolve
DNS domain name
11: invalidHostAddress: Invalid host address
LastRC
Response code in the last ICMP response packet
received. (The device does not support this field at
present, so that this field is always displayed as 0)
Time
Test completion time
# Display the result of the test group with the administrator name being administrator,
and the operation tag being http.
[Sysname-hwping-administrator-http] display hwping results administrator
http
HWPing entry(admin administrator, tag http) test result:
Destination ip address:192.168.0.152
Send operation times: 10 Receive response times: 10
Min/Max/Average Round Trip Time: 47/87/74
Square-Sum of Round Trip Time: 57044
Last succeeded test time: 2000-4-2 20:41:50.4
Extend result:
SD Maximal delay: 0 DS Maximal delay: 0
Packet lost in test: 0%
Disconnect operation number: 0 Operation timeout number: 0
System busy operation number: 0 Connection fail number: 0
Operation sequence errors: 0 Drop operation number: 0