77
Item
S5024PV3-EI-PWR
S5024PV3-EI-HPWR
S5048PV3-EI-PWR
chassis left side and port
side and exhaust hot air
from the right side
chassis left side and port
side and exhaust hot air
from the chassis right side
chassis left side and exhaust
hot air from the chassis right
side
Operating
temperature
–5°C to +45°C (23°F to 113°F)
Operating
humidity
5% RH to 95% RH, noncondensing
Fire
resistance
compliance
UL60950-1/EN60950-1/IEC60950-1/GB4943
S5500V3-SI switch series
Table 20 Technical specifications for S5500V3-SI switch models
Item
S5500V3-24P-SI
S5500V3-48P-SI
Dimensions (H × W
× D)
43.6 × 440 × 160 mm (1.72 × 17.32 ×
6.30 in)
43.6 × 440 × 230 mm (1.72 × 17.32 × 9.06 in)
Weight
≤ 2.5 kg (5.51 lb)
≤ 3.5 kg (7.72 lb)
Console port
•
1 × micro USB console port
•
1 × serial console port
Only the micro USB console port is
available when you connect both
ports.
•
1 × micro USB console port
•
1 × serial console port
Only the micro USB console port is available
when you connect both ports.
10/100/1000BASE-
T autosensing
Ethernet port
24
48
SFP port
2
2
SFP+ port
2
2
Input voltage
•
Rated voltage: 100 VAC to 240 VAC @ 50 or 60 Hz
•
Max voltage: 90 VAC to 264 VAC @ 47 to 63 Hz
Minimum power
consumption
10 W
19 W
Maximum power
consumption
24 W
44 W
Chassis leakage
current compliance
UL60950-1/EN60950-1/IEC60950-1/GB4943
Melting current of
power module fuse
2 A/250 V
3.15 A/250 V
Cooling system
Using fixed fan trays to intake cool
air from the chassis left side, right
side, and port side and exhaust hot
air from the power module side
Using fixed fan trays to intake cool air from the
chassis left side and exhaust hot air from the
chassis right side and power module side
Operating
temperature
–5°C to +45°C (23°F to 113°F)