5
exhausted from the air outlet vents. If there is no air being exhausted from the air outlet vents,
remove and reinstall the fan tray. Then execute the
display fan
command to verify that the
fan tray has changed to
Normal
state. If the fan tray remains in
Fault
state, replace the fan tray.
If there is no new fan tray, power off the switch to avoid damage caused by high
temperatures.
If there are cooling measures to maintain the switch operating temperature below 60°C
(140°F), the switch can be used temporarily.
4.
If the issue persists, contact H3C Support.
Related commands
This section lists the commands that you might use for troubleshooting the hardware.
Command
Description
dir
Displays information about files and directories.
display boot-loader
Displays current configuration files and system software
images.
display environment
Displays temperature information.
display fan
Displays the operating states of the fan tray.
display logbuffer
Displays the state of the log buffer and the log information in
the log buffer.
display power
Displays power supply information.