20
Temperature alarms
Symptom
Temperature alarms occur.
Troubleshooting flowchart
Figure 4 Troubleshooting temperature alarms
Solution
To resolve the issue:
1.
Check the ambient temperature. If the ambient temperature is higher than 22 °C (71.6°F), lower
the temperature by adding air conditioners or taking other heat dissipation measures.
2.
Check the device temperature. If the device temperature is higher than the high-temperature
warning threshold, use the
display fan
command to verify that the fans a operating correctly.
If the status of a fan is
Fault
, replace the fan.
3.
Check whether the air filters are clean. If they are not, clean them.
Temperature alarm
Device
temperature
too high?
Y
Resolved?
N
N
Y
Air filters clean?
Clean air filters
N
Y
Y
N
Contact the support
End
Resolved?
Resolve fan
issues
Ambient
temperature
too high?
Y
Resolved?
N
Y
Lower the
temperature
N
Y
Y
N
Temperature
alarm threshold
adjusted?
Replace the
device
N
Resolved?
N