26
a.
Execute the
debug port optical-eeprom
command to save the transceiver module
information.
[Sysname-probe]debug port optical-eeprom 1 0 25 0 160 0 128
The eeprom information of HundredGigE1/0/25:
=======================================================================
0x00: 00 00 02 00 00 00 00 00 00 00 00 00 00 00 00 00
0x10: 00 00 00 00 00 00 1f 06 1f 06 81 58 00 00 00 00
0x20: 00 00 00 00 00 00 00 00 00 07 00 00 00 00 00 00
0x30: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
0x40: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
0x50: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
0x60: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 81 28
0x70: 21 4d 00 00 00 00 00 00 00 00 00 00 00 00 00 01
b.
Provide the information to H3C Support to verify that the transceiver module is an H3C
transceiver module. If it is not, replace it with an H3C transceiver module.
3.
If the issue persists, contact H3C Support.
Transceiver module does not support digital
diagnosis
Symptom
The output from the
display transceiver diagnosis interface
command shows that the
transceiver module does not support the digital diagnosis function.
<Sysname> display transceiver diagnosis interface HundredGigE1/0/25
Error: The transceiver does not support this function.
Troubleshooting flowchart
Figure 8 Troubleshooting digital diagnosis failure on a transceiver module
Transceiver module
supports digital diagnosis?
Replace it with an H3C
transceiver module
System prompted that the
transceiver module does not
support digital diagnosis
No
Yes
No
Yes
No
Yes
Contact the support
End
Resolved?
H3C transceiver module?