37
remote fault
—When the local fault occurs on a remote port, the remote end sends a
message to the local end. A remote fault prompt message appears on the local device,
which indicates that no fault exists on the local device in the direction of receiving packets.
In this case, assist in troubleshooting the remote end.
MAC faults are not directly related to MAC addresses. If the issue persists after you remove the
link and module problems, contact H3C Support.
[probe] debug port link-diag slot 2 0 1 0
Chassis 0 Slot 2/port/tgid:0 operation record, need be translated with code and line
num
[0]:PID=128 TName=FMCK Line=5161 03/24/2016 13:26:26:369
m0=92 m1=1 m2=1 drv_port_opticmod_check_port_in
[7]:PID=193 TName=kifup Line=8592 03/24/2016 13:26:25:104
m0=1 m1=0 m2=0 drv_port_platform_event_notify
Slot:2/0 link down reason.
[0]: CallLine=1314 Time=03/23/2016 14:03:55:610
linkinfo=0xfd down. pma. pcs. xgs. fault. localfault
[9]: CallLine=1314 Time=03/23/2016 05:05:14:565
linkinfo=0xbd down. pma. pcs. xgs. fault. rmtfault
4.
Execute commands in the following table to collect information and contact H3C Support.
Command
Description
display transceiver diagnosis
interface
Displays the current values of the digital diagnosis
parameters on transceiver modules.
display transceiver interface
Displays the key parameters of transceiver
modules.
display transceiver manuinfo
interface
Displays electronic label information for
transceiver modules.
display transceiver information
interface
Displays transmission information for transceiver
modules.
bcm slot 6 chip 0 phy/control/xl1/dump
Collects the port register information. (This
operation will not cause flapping of ports on the
same chip. To see the xl1 port name. execute the
debug port mapping slot
command.)
CRC error packets on a port
Symptom
A large number of CRC error packets exist on the local or remote port.