40
Troubleshooting flowchart
Figure 16 Troubleshooting IRF fabric setup failure
Solution
To resolve the issue:
1.
Execute the
display irf
command to verify that the number of member devices in the IRF
fabric does not reach the upper limit.
No
Yes
No
Yes
No
Yes
End
No
No
Yes
Yes
Yes
Contact the
support
No
Yes
Resolved?
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
You cannot add a new
member to the fabric
Yes
No
Same device model?
Replace with a device that
is the same model as
existing IRF member
devices
Assign a unique member
ID to the device
Number of member devices
fewer than the upper limit?
Member ID unique?
No
Resolved?
Physical IRF
connections correct?
Modify IRF port bindings
or reconnect physical
interfaces
Resolved?
IRF links up?
Remove link failure
conditions to bring up the
IRF links
Resolved?
Same software version?
Upgrade the device with
the software version
running in the IRF fabric
Resolved?
Bridge MAC unique?
Remove the duplicate
bridge MAC condition
Resolved?
IRF setup
failure