12
Input Power:132W
PowerID State InPower(W) Current(A) Voltage(V) OutPower(W) Type
1 Absent -- -- -- -- ---
2 Normal -- -- -- -- PSR300-A
If the voltage and current of the power module are
0
and the power module state is
Fault
,
the power cord is disconnected. Connect the power cord securely to the power module.
Then execute the
display power
command to verify that the power module has changed
to
Normal
state.
b.
Determine whether the power module is in high temperature. If dust accumulation on the
power module causes the high temperature, remove the dust. Then remove and reinstall
the power module. Execute the
display power
command to verify that the power module
has changed to
Normal
state.
c.
Install the power module into an empty power module slot. Then execute the
display
power
command to verify that the power module has changed to
Normal
state in the new
slot. If the power module remains in
Fault
state, replace the power module.
4.
If the issue persists, contact H3C Support.
Newly
installed power module failure
Symptom
A newly installed power module fails.
Solution
To resolve the issue:
1.
Identify the operating state of the power module.
Execute the
display power
command to view the operating state of the power module.
<Sysname> display power
Input Power:132W
PowerID State InPower(W) Current(A) Voltage(V) OutPower(W) Type
1 Absent -- -- -- -- ---
2 Normal -- -- -- -- PSR300-A
Execute the
display alarm
command to view alarm information about the power module.
<Sysname> display alarm
Slot CPU Level Info
1 0 INFO Chassis 1 power 1 is absent.
If the power module is in
Absent
. If the power module is in
Fault
state, go to
step
2.
Verify that the power module is installed securely.
a.
Remove and reinstall the power module to make sure the power module is installed
securely. Then execute the
display power
command to verify that the power module has
changed.
b.
Remove and install the power module into an empty power module slot. Then execute the
display power
command to verify that the power module has changed to
Normal
state
in the new slot. If the power module remains in
Absent
state, go to step
3.
Verify that the power module is operating correctly.