42
NOTE:
Typically, the software auto-update feature can automatically synchronize a member device
with the software version of the master device. However, the synchronization might fail when
the gap between the software versions is large.
7.
Verify that the device has a unique bridge MAC address:
a.
Execute the
display interface vlan-interface 1
command, and then check the
Hardware Address
field.
[Sysname] display interface vlan-interface 1
Vlan-interface1 current state: UP
Line protocol current state: UP
Description: Vlan-interface1 Interface
The Maximum Transmit Unit is 1500
Internet protocol processing : disabled
IP Packet Frame Type: PKTFMT_ETHNT_2, Hardware Address: 0023-8912-3d07
IPv6 Packet Frame Type: PKTFMT_ETHNT_2, Hardware Address: 0023-8912-3d07
b.
If the device has the same bridge MAC address as the IRF fabric, remove the bridge MAC
conflict.
8.
If the issue persists, execute the
display diagnostic-information
command and collect
the device diagnostic information, and then send the information to contact H3C Support.
IRF split
Symptom
An IRF fabric splits.
Troubleshooting flowchart
Figure 17 Troubleshooting IRF split
End
IRF fabric
splits
Contact the support
Member device rebooted?
Identify the cause and
resolve the issue
Yes
No
Resolved?
No
Yes
IRF physical interfaces down?
Identify the cause and
resolve the issue
Yes
No
Resolved?
No
Yes