Command Manual – PoE
H3C S7500 Series Ethernet Switches
Chapter 2 PoE PSU Supervision Configuration
Commands
2-4
Table 2-3
Description on the fields of the
display poe-power dc-output state
command
Field
Description
Normal: The DC output is normal.
Under Limit: The DC output voltage is
lower than the lower threshold.
Upper Limit: The DC output voltage is
higher than the upper threshold.
Fuse Broken: The fuse is broken.
Switch Off: The switch is off.
DC output state of the external PoE PSU
Hardware Fault: Hardware fails.
2.1.4 display poe-power dc-output value
Syntax
display poe-power dc-output value
View
Any view
Parameters
None
Description
Use the
display poe-power dc-output value
command to display the DC output
voltage/current values of the external PoE PSUs.
Examples
# Display the DC output voltage/current values of the external PoE PSUs.
<H3C> display poe-power dc-output value
DC Output Voltage : 53.997
DC Output Current : 0.350 A