13
•
Stop bits
—1.
•
Parity
—None.
•
Flow control
—None.
Powering on the switch
1.
Make sure the power cords are connected correctly to the power source, and the power source is
supplying power correctly.
2.
Turn on the circuit breakers for the power modules.
3.
Power on the switch.
4.
Verify that the LEDs on the switch are in the states as described
about the LEDs, see
H3C S7508E-X Switch Installation Guide
.
Table 4
LED status when the switching is operating correctly
Card LED
Status
MPU
LINK Steady
on
ACT
Flashing or off
OK Steady
on
FAIL Off
RUN Flashing
ALM
Flashing or off
Switching fabric module
RUN
Flashing or steady on
ALM Off
Power module
Power input
Steady green
Power output
Steady green
Fan tray
OK Steady
on
FAIL Off
Obtaining documentation
Take the following steps to get related documents from the H3C websit.
1.
Go to
Choose the desired product category and model.