3
Examining the installation site
The switch can only be used indoors. To make sure the switch operates correctly and prolong its service
lifetime, the installation site must meet the requirements for load-bearing, temperature, humidity,
cleanness, EMI, grounding power module, ventilation, and space. For more information, see
H3C
S7508E-X Switch Installation Guide
.
If you are to install the switch in an enclosed rack, make sure the rack meets the following requirements:
•
A minimum of 100 mm (3.94 in) distance between the front rack posts and the front door for
accommodating the cable management brackets.
•
A minimum of 710 mm (27.95 in) distance between the front rack posts and the rear door for
accommodating the chassis and card handles.
Installing the switch
Attaching the slide rails to the rack
1.
Read the signs on the slide rails to identify the left and right slide rails and their front ends, as
Table 3
Description for signs on the slide rails
Sign
Meaning
Remarks
F/L
Front end of the left slide rail
Mount this end to the front left rack post.
F/R
Front end of the right slide rail
Mount this end to the front right rack post.
2.
Mark the installation position on the rack for the slide rails:
a.
Make sure the top flange of a slide rail aligns with the middle of the narrower metal area
between holes in a rack post, as shown in
.
b.
Each rack post requires six screws to attach the slide rail. Mark only the uppermost and
lowermost holes.
c.
Mark the square holes at the same height on the other three rack posts.