background image

Quick Start 
H3C SecPath F100-C-EI Firewall

 

Chapter 1  Firewall Overview

 

1-1

 

Chapter 1  Firewall Overview 

1.1  Introduction 

The H3C SecPath F100-C-EI Firewall (hereinafter referred to as 

the F100-C-EI) is a new-generation firewall intended for small office 

home office (SOHO) use. 

 

The F100-C-EI has the following features: 

 

z

 

Provides uplink WAN interface compliant to international 

standard, ensuring the interoperability with the products of 

other vendors. 

z

 

Provides five 10/100 Mbps auto-sensing Ethernet interfaces 

that can be assigned to different security zones, such as 

Trust, DMZ, Untrust and management security zones.  

z

 

Supports internal temperature detection, network 

management, and Web-based management, satisfying 

carrier-class reliability requirements. 

z

 

Supports such features as external attack defense, TCP 

proxy, internal network security, traffic policing, web filtering, 

and email filtering, to effectively safeguard your network. 

z

 

Adopts the application specific packet filtering (ASPF) 

technology to monitor connection process and unauthorized 

operations, and works together with access control lists 

(ACLs) to implement dynamic packet filtering. 

Summary of Contents for SecPath F100-C-EI

Page 1: ...H3C SecPath F100 C EI Firewall Quick Start Hangzhou H3C Technologies Co Ltd http www h3c com Manual Version 5PW100 20080729...

Page 2: ...G Vn G PSPT XGbus N Bus TiGem InnoVision and HUASAN are trademarks of Hangzhou H3C Technologies Co Ltd All other trademarks that may be mentioned in this manual are the property of their respective o...

Page 3: ...nd applications of the H3C SecPath F100 C EI Firewall 2 Connecting Cables Guides you through how to connect PGND wires power cord and console cables for the H3C SecPath F100 C EI Firewall Appendix Com...

Page 4: ...ful Improper operation may cause bodily injury Caution Means reader be careful Improper operation may cause data loss or damage to equipment Note Means a complementary description Related Documentatio...

Page 5: ...ation Manual Guides you through configuring the H3C SecPath series firewalls through Web interfaces Obtaining Documentation You can access the most up to date H3C product documentation on the World Wi...

Page 6: ...entation to info h3c com We appreciate your comments Environmental Protection This product has been designed to comply with the requirements on environmental protection For the proper storage use and...

Page 7: ...Contents i Table of Contents Chapter 1 Firewall Overview 1 1 1 1 Introduction 1 1 1 2 Technical Specifications 1 3 Chapter 2 Connecting Cables 2 1 2 1 Connecting the PGND Wire 2 1 2 2 Connecting the...

Page 8: ...Mbps auto sensing Ethernet interfaces that can be assigned to different security zones such as Trust DMZ Untrust and management security zones z Supports internal temperature detection network managem...

Page 9: ...nstructed on the open Internet z Supports multiple virtual private network VPN services such as Layer 2 tunneling protocol L2TP VPN IP security IPSec VPN generic routing encapsulation GRE VPN and dyna...

Page 10: ...100 Mbps Ethernet interface 4 10 100 Mbps Ethernet ports LAN and WAN SDRAM Default 64 MB Max 64 MB Flash memory 8 MB Rated voltage range 100 VAC to 240 VAC 50 Hz or 60 Hz Maximum input current 0 4 A...

Page 11: ...ection ground PGND wire is essential for safeguarding the firewall against lightning shocks and interference Therefore first correctly connect the PGND wire before installing and using the firewall Th...

Page 12: ...ollow the steps 1 Remove the grounding screw from the chassis 2 Insert the grounding screw into the OT terminal of the PGND wire 3 Fix the grounding screw with the OT terminal to the grounding hole in...

Page 13: ...commended to use a three wire single phase power socket with a neutral point z The neutral point of the socket must be grounded reliably Normally the neutral point of the power source in a building wa...

Page 14: ...onsole cable 1 Select a console terminal The console terminal can be a standard ASCII terminal possessing an RS 232 serial port or more often a common PC 2 Connect the console cable Disconnect the fir...

Page 15: ...Quick Start H3C SecPath F100 C EI Firewall Chapter 2 Connecting Cables 2 5 Figure 2 2 Connect the console cable...

Page 16: ...CC Part 15 A 3 A 4 Canada regulatory compliance A 4 A 4 1 ICES 003 A 4 A 5 Japan regulatory compliance A 4 A 5 1 VCCI A 4 A 6 CISPR 22 compliance A 5 Appendix B Safety Information Sicherheits informat...

Page 17: ...ation A 1 Regulatory compliance standards Table A 1 Regulatory compliance standards Discipline Standards EMC FCC Part 15 CFR 47 CLASS A ICES 003 CLASS A VCCI 3 CLASS A VCCI 4 CLASS A CISPR 22 CLASS A...

Page 18: ...60950 1 EN 60950 1 A11 AS NZS 60950 A 2 European Directives compliance A 2 1 LVD EMC Directive H3C SecPath F100 C EI product complies with the European Low Voltage Directive 2006 95 EC and EMC Directi...

Page 19: ...of the FCC Rules Operation is subject to the following two conditions z This device may not cause harmful interference z This device must accept any interference received including interference that m...

Page 20: ...gy and if not installed and used in accordance with the instruction anual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause ha...

Page 21: ...When such trouble occurs the user may be required to take corrective actions A 6 CISPR 22 compliance H3C SecPath F100 C EI complies with the requirements of CISPR 22 for Class A Information Technology...

Page 22: ...s part of the safety precautions that should be followed during the installation and maintenance of the equipment And for the safety statements and warnings there followed the translations of both Ger...

Page 23: ...ce of the products are required to understand these basics of safety operation In performing various operations please follow the local safety regulations The safety precautions introduced in the prod...

Page 24: ...onal mit allen Sicherheitshinweise vertraut machen Bei der Durchf hrung der verschiedenen Arbeitsschritte m ssen au erdem die rtlichen Sicherheitsvorschriften beachtet werden Die in den Handb chern de...

Page 25: ...the following table They are used to remind the reader of the safety precautions during equipment installation and maintenance Die Symbole in diesem Handbuch verwendeten sind in der folgenden Tabelle...

Page 26: ...Alarm Hinweis auf ein generelles Sicherheitsproblem ESD protection symbol To suggest electrostatic sensitive equipment ESD Schutz Hinweis auf Besch digung infolge elektrostatischer Entladung Electric...

Page 27: ...rd und das die Erdverbindung stets als letztes getrennt wird z z Do not block ventilation openings while the system is on and keep at least 5 cm distance from ventilation openings and walls or other t...

Page 28: ...igen Inbetriebnahme geerdet werden Der Querschnitt der Erdverbindung sollte mindestens 0 75mm2 betragen z 0 75mm2 z For AC supplied model The device applies to TT power systems z Mit Wechselstrom betr...

Page 29: ...offers electric power for equipment operation Direct contact or indirect contact via damp objects with high voltage and AC mains supply may result in fatal danger Gefahr Die Hochspannungsleitungen ste...

Page 30: ...ducting articles such as watch hand chain bracelet and ring are prohibited during the operation z Es ist nicht erlaubt w hrend dieser Arbeiten leitende Gegenst nde wie Uhren Armb nder Armreifen und Ri...

Page 31: ...local rules and regulations The personnel who perform high voltage operations should be qualified for high voltage and AC operations Warnung Die Nichtbeachtung der Sicherheitsvorschriften bei der Arb...

Page 32: ...ibited strictly Transient contact between the core of power cable and conductor may generate electric arc or spark or electric arc which may lead to fire or eye injury Anmerkung Das Entfernen und Anbr...

Page 33: ...ltet werden bevor die Zuleitung angebracht oder entfernt wird z z Before the power cable is connected it must be confirmed that the power cable and label comply with the requirements of the actual ins...

Page 34: ...betriebene Ausr stung benutzen Sie bitte eine 0 75 mm2 oder 18 AWG Zuleitung AC 0 75mm2 18 AWG B 2 3 Thunderstorm Gewitter Danger High voltage and AC operations or operations on a steel tower and a ma...

Page 35: ...echselstrom oder Arbeiten auf Stahlt rmen und masten w hrend eines Gewitters sind verboten Um die Ausr stung vor Besch digung durch Blitzschlag zu sch tzen ist eine ordnungsgem e Erdung erforderlich A...

Page 36: ...3C SecPath F100 C EI Firewall Appendix B Safety Information Sicherheits informationen B 15 Warnung Ersetzen Sie die Sicherung bei Bedarf immer nur mit einem Sicherungstyp der die gleichen technischen...

Reviews: