Installation Manual
H3C SecPath F100-C Firewall
Chapter 6 Troubleshooting
6-2
I. Troubleshooting no display on terminal screen
1) Symptom:
Nothing is displayed on the terminal screen after the H3C
SecPath F100-C is powered on.
2) Solution:
Step 1
: Check that:
z
The PSU is operating normally.
z
The console cable is connected correctly.
Step 2
: If no problem is found, examine the parameters
configured at the terminal (such as HyperTerminal), or check the
console cable.
II. Troubleshooting illegible characters on the terminal
screen
1) Symptom:
Illegible characters are displayed on the console terminal after
the H3C SecPath F100-C is powered on.
2) Solution:
Make sure you have set on your terminal (HyperTerminal):
Bits per second = 9600
Data bits = 8
Parity = None
Stop bits = 1
Flow control = None
Emulation = VT100/auto-detect