4-29
Replacing an interface module
CAUTION:
•
Interface modules are not hot swappable. Power off the firewall before you replace an interface
module.
•
To install two or more interface modules, use the upper interface module slots as a best practice.
If you have installed an interface module in a lower slot, you must press down the ejector levers
of the interface module while inserting it into an upper slot.
For the interface modules available for the firewall, see "Appendix A Chassis views and technical
specifications."
To replace an interface module:
1.
Power off the firewall.
2.
Use a Phillips screwdriver to loosen the captive screws of the interface module.
3.
Holding the ejector levers of the interface module with both hands, pull the ejector levers
outward, and pull the interface module part way out of the slot along the slide rails. Supporting
the bottom of the interface module with one hand, gently pull the interface module out of the slot
with the other.
4.
Put the removed interface module (with the circuit board facing upward) on an antistatic
workbench or into an antistatic bag.
5.
Install a new interface module. For the installation procedure, see "
If you are not to install a new interface module, install a filler panel in the slot to ensure good
ventilation in the firewall.
Figure4-2 Removing an interface module
Replacing a drive
CAUTION:
•
To avoid storage medium damage, execute the
umount
command from the CLI to unmount all
partitions before removing a drive.
•
Drives are not hot swappable.
To replace a drive:
1.
Wear an ESD wrist strap and make sure it makes good skin contact and is reliably grounded.
2.
Press the button on the drive panel to release the locking lever.
3.
Hold the locking lever and pull the drive out of the slot.
3
2
2
1
1
Summary of Contents for SecPath F100-X-G3
Page 63: ...i Contents 1 Appendix B LEDs 1...