Installation Manual
H3C SecPath F1000-E Firewall
Chapter 1 Product Overview
1-15
Note:
z
For a GE combo interface, the default operating interface is the optical Ethernet
interface.
z
For a GE combo interface, you can use either the electrical Ethernet interface or the
optical Ethernet interface. You can use the
combo enable
{
copper
|
fiber
}
command in interface view to switch between the optical and electrical Ethernet
interfaces.
2) Technical specifications for GE combo interface
z
Technical specifications for electrical Ethernet interface
Table 1-14
Technical specifications for electrical Ethernet interface
Item
Specification
Connector
RJ-45
Interface
Autosensing
When working in the forced mode, Ethernet does not support
MDI/MDI-X autosensing.
Frame format
Ethernet_II
Ethernet_SNAP
10 Mbps (autosensing)
Half/full-duplex auto-negotiation
100 Mbps (autosensing)
Half/full-duplex auto-negotiation
Rate and
negotiation mode
1000 Mbps (autosensing)
Full-duplex
Note:
The media dependent interface (MDI) is a typical Ethernet interface provided by
network adapters. The media dependent interface crossover (MDI-X) is commonly
found on hubs or LAN switches.
z
Technical specifications for optical Ethernet interfaces
Table 1-15
Technical specifications for 1000 Mbps optical Ethernet interfaces
Item
Specification
Connector
SFP/LC
Compliant
standard
802.3, 802.3u, and 802.3ab