Installation Manual
H3C SecPath F1000-E Firewall
Chapter 4 Installing the Firewall
4-12
4.9 Connecting the Power Cables
4.9.1 Power Supply Port and PGND Terminal
The F1000-E only supports AC power input. The AC power socket and power switch
are located on the left of the front panel, as shown in Figure 4-11.
(1)
(2)
(3)
(1) Bail latch holder
(2) AC power socket (100 V to 240V; 50/60Hz; 2.5A)
(3) Power switch
Figure 4-11
AC power socket
For the specifications for the AC power socket, see Table 4-2.
Table 4-2
Technical specifications for the AC power socket of the F1000-E
Item
Specification
AC power socket
100 VAC to 240 VAC
4.9.2 Connecting the AC Power Cord
I. AC power supply
Rated voltage range: 100 VAC to 240 VAC, 50 Hz/60 Hz.
II. AC power socket
z
Use a three-terminal, single-phase power connector with a grounding contact
z
Ground the power supply reliably. Normally, the grounding contact of the power
supply system in a building was buried during construction and cabling.
z
Before connecting the AC power cord, make sure that the power supply of the
building is well grounded.