Installation Manual
H3C SecPath F1000-E Firewall
Chapter 8 Troubleshooting
8-4
8.6 Troubleshooting the Cooling System
I. Symptom
The temperature inside the firewall exceeds 45°C (113°F).
II. Solution
z
Check whether the fans are running normally.
z
Check whether the working environment of the firewall is well ventilated.
z
If the temperature inside the firewall exceeds 60°C (140°F), the following
information appears on the configuration terminal:
%Jun 28 10:27:27:653 2007 H3C DRVMSG/3/Temp2High:
Environment temperature too high in Slot 0, index is 1.
#Jun 28 10:27:28:432 2007 H3C DEV/1/BOARD TEMPERATURE UPPER:
Trap
1.3.6.1.4.1.2011.2.23.1.12.1.16<hwBoaardTemperatureHigher>:frameIndex is
0, slotIndex 0.0
%Jun 28 10:27:28:433 2007 H3C DEV/4/BOARD TEMP TOOHIGH:
Board temperature is too high on Frame 0 Slot 0, type is RPU.
z
Use the
display environment
command to check whether the temperature in the
firewall keeps rising. If the temperature inside the firewall exceeds 90°C (194°F),
power off the firewall immediately and contact your local sales agent.
Note:
For more information about the
display environment
command, refer to
H3C SecPath
Series Security Products User Manual
.
8.7 Troubleshooting Interface Modules, Cables and
Connections
I. Symptom
After the HIM is installed and the firewall is powered on, the LED on the HIM panel
indicates abnormal operation.
II. Solution
Check that:
z
The HIM cable was correctly selected.