No fan tray is provided with the firewall. Purchase fan trays as required. The firewall supports the
FAN-20B-2-A and FAN-20F-2-A fan trays that are hot swappable.
The installation procedures for the FAN-20B-2-A and the FAN-20F-2-A fan trays are similar. The
following procedure installs a FAN-20B-2-A fan tray.
To install a fan tray:
1.
Wear an ESD wrist strap and make sure it makes good skin contact and is reliably grounded.
2.
Orient the fan tray with the "TOP" mark on the top, grasp the fan tray handle with one hand, and
support its bottom with the other hand. Slide the fan tray along the guide rails into the slot until it
has a firm contact with the backplane.
Figure2-8 Installing a fan tray
Installing an MPU or an interface module
CAUTION:
•
Only slots 0/0 and 1/0 on the F5030-D/F5060-D/F5080-D support installation of MPUs.
•
If the F5030-D/F5060-D/F5080-D is installed with two MPUs, you can hot swap an MPU. If the
F5030-D/F5060-D/F5080-D is installed with only one MPU, you cannot hot swap the MPU.
•
Interface modules are not hot swappable.
•
To avoid module damage, do not touch the surface-mounted components on an interface module
directly with your hands.
•
Install a filler panel over empty MPU and interface module slots to prevent dust and ensure good
ventilation in the chassis.
No MPU or interface module is provided with the firewall. Purchase them as required. The
installation procedure is the same for MPUs and interface modules.
To install an interface module:
1.
Wear an ESD wrist strap and make sure it makes good skin contact and is reliably grounded.
2.
Remove the screws on the filler panel with a Phillips screwdriver and remove the filler panel.
Keep the filler panel for future use.