30
Figure 2-30 Routing cables (M9000-AI-E16 gateway)
(Optional) Installing air filter doors
The M9000-AI gateway supports air filter doors. For more information about installing air filter doors,
see the installation guide for the air filter doors.
Verifying the installation
Table 2-6 Post-installation checklist
Item
Requirements
Installation site
•
No condensation on the surface of the gateway or inside of the gateway.
•
Keep the gateway clean and dust-free.
•
No packing boxes, packing bags or other packing materials left in the installation
site.
•
Keep the air inlet and outlet vents of the gateway free of obstruction.
Gateway
•
All modules are installed correctly.
•
No slot is empty. Each is installed with a module or filler panel,
•
Fan trays are installed correctly.
Cables
•
The gateway is grounded reliably with the provided grounding cable. Both ends of
the grounding cable are securely connected.
•
No switch or fuse is installed on the grounding cable.
•
The power cords are connected reliably and no short circuit has occurred in
power input and output.