Installation Manual
H3C SecPath V100-S Security Gateway
Chapter 5 Software Maintenance
5-3
Caution:
You are recommended to upgrade the software under the guidance of technical
support engineers. When upgrading the security gateway, make sure that the version
of the Boot ROM software is consistent with the application program.
5.2 Upgrading Application and Boot ROM Using XModem
You can use XModem through the console port to upgrade the software even without
setting up a configuration environment.
I. Upgrading the application program
Step 1: Enter the Boot Menu (see 5.1 “Boot Menu”) and select <1> to download an
application program using XModem. The security gateway supports these downloading
speeds:
Downloading application program from serial ...
Please choose your download speed:
1: 9600 bps
2: 19200 bps
3: 38400 bps
4: 57600 bps
5: 115200 bps
6: Exit to Main Menu
Enter your choice(1-6):
Step 2: Select an appropriate downloading speed, (for example, 115200 bps by
entering <5>). The system displays:
Download speed is 115200 bps. Change the terminal's speed to 115200 bps, and
select XModem protocol. Press ENTER key when ready.
Step 3: Change your terminal’s baud rate (see Figure 4-4) to the same baud rate for
software downloading (115200 bps in this example). After that, disconnect the terminal
([Dial-in/Disconnect]), reconnect it ([Dial-in/Dialing]), and press <Enter> to start
downloading. Then the system displays:
Downloading ... CCCCC