Installation Manual
H3C SecPath V1000-A Security Gateway
Chapter 3 Hardware Installation
3-4
(1) Grounding screw
Figure 3-3
Grounding screw on the SecPath V1000-A
Connect this screw to the earth ground using a grounding wire. The grounding
resistance must be smaller than 5 ohm. If the device is mounted in a 19-inch standard
rack, the rack must be earthed.
Caution:
Lightning strikes can damage your device and the connected device as well. For
secure lightning protection, make sure that your security gateway has a good ground
connection when it is operating.
3.5 Connecting to the Console Terminal
I. Console port
On the security gateway, one RS232 asynchronous serial console port is available for
you to configure the device. For the attributes of the console port, refer to the section
“1.2.4 Attributes of the Fixed Interfaces”.
II. Console cable
Console cable is an 8-wire shielded cable. At one end of the cable is an RJ45 connector
to the console port on the security gateway; at the other end is a DB9 (female)
connector to the serial port of the console terminal.