8.4.6 Connecting the Interface Cable
Step 1: Plug one end of the cable to an Ethernet port of the FE module on the security
gateway and another end to the desired device. (For a PC or Router, use a
straight-through cable; for a HUB or LAN Switch, use a crossover cable.)
Step 2: Power up the security gateway and check status of the LINK LED on the FE
module. ON means a link is present. OFF means no link is present and you should
check the connection.
Caution:
Read the mark of a port carefully before you connect it; a wrong connection can cause
damages to the interface module and even the device.
8.5 1GBE/2GBE Module
8.5.1 Introduction
1-/2-port 10Base-T/100Base-T/1000Base-TX Ethernet interface module (1GBE/2GBE)
can provide the communications between the SecPath V1000-A and a LAN.
The 1GBE/2GBE module supports:
z
The transmission distance of 100 meters over category-5 twisted-pair cable
z
Three operating rates: 1000 Mbps, 100 Mbps, and 10 Mbps, with auto-sensing
z
Full-duplex mode
8.5.2 Appearance
Figure 8-9 and Figure 8-10 show respectively the 1GBE and 2GBE module.