Activating Patches
After you activate a patch, the patch takes effect and is in the test-run stage. After the device is reset or
rebooted, the patch becomes invalid.
If you find that an ACTIVE patch is of some problem, reboot the device to deactivate the patch, so as to
avoid a series of running faults resulting from patch error.
Follow these steps to activate patches: (On the SR6602 router)
To do…
Use the command…
Remarks
Enter system view
system-view
—
Activate the specified patches
patch active patch-number
Required
Follow these steps to activate patches: (On the SR6604/6608/6616 router)
To do…
Use the command…
Remarks
Enter system view
system-view
—
Activate the specified patches
patch active patch-number
slot
slot-number
Required
Confirming Running Patches
After you confirm the running of a patch, the patch state becomes RUNNING, and the patch is in the
normal running stage. After the device is reset or rebooted, the patch is still valid.
Follow these steps to confirm the running of the patches: (On the SR6602 router)
To do…
Use the command…
Remarks
Enter system view
system-view
—
Confirm the running of the
specified patches
patch run patch-number
Required
Follow these steps to confirm the running of patches: (On the SR6604/6608/6616 router)
To do…
Use the command…
Remarks
Enter system view
system-view
—
Confirm the running of the
specified patches
patch run patch-number
[
slot
slot-number
]
Required
This operation is applicable to patches in the ACTIVE state only.