3-46
To do…
Use the command…
Remarks
Set the maximum
number of lines on the
next screen
screen-length screen-length
Optional
By default, the next screen
displays 24 lines.
A value of 0 disables the function.
Set the size of history
command buffer
history-command max-size
value
Optional
By default, the buffer saves 10
history commands.
Set the idle-timeout
timer
idle-timeout minutes
[
seconds
]
Optional
The default idle-timeout is 10
minutes for all user interfaces.
The system automatically
terminates the user’s connection if
there is no information interaction
between the device and the user in
timeout time.
Setting idle-timeout to 0 disables
the timer.
Specify a command
to be automatically
executed when a user
logs in to the current
user interface
auto-execute command
command
Optional
By default, command
auto-execution is disabled.
The system automatically executes
the specified command when a
user logs in to the user interface,
and tears down the user
connection after the command is
executed. If the command triggers
another task, the system does not
tear down the user connection until
the task is completed. A telnet
command is usually specified to
enable the user to automatically
telnet to the specified device.
The
auto-execute command
command may disable you from configuring the system through the user
interface to which the command is applied. Therefore, before configuring the command and saving the
configuration (by using the
save
command), make sure that you can access the device through VTY,
TTY, console, or AUX interfaces to remove the configuration when a problem occurs.
Configuring the Device to Log In to Another Device as a Telnet Client
Configuration prerequisites
You have logged in to the device.
By default, you can log in to the device through the console port without authentication and have user
privilege level 3 after login. For how to log in to the device with default configuration, see
.