58 

Item Specification 

Interface speed and duplex 
mode 

10 Mbps auto-sensing 

Half/full duplex, auto-negotiation 

100 Mbps auto-sensing 

Half/full duplex, auto-negotiation 

1000 Mbps auto-sensing 

Full duplex, auto-negotiation 

 

For the combo fiber port specifications, see 

Table 69

. For the transceiver module available for the combo 

fiber ports, see 

Table 70

 

 

NOTE: 

Use transceiver modules provided by H3C only. The router might be incompatible with other transceiver 
modules. 

 

Interface cables 

Use the following cables for the SAP-28GE ports: 

 

SFP port

—An SFP transceiver module and a fiber that has an LC connector. 

 

Combo copper port operating at 10/100 Mbps

—Category-5 straight-through/crossover network 

cables. 

 

Combo fiber port operating at 1000 Mbps

—Category-6 network cables. 

For the appearance and connection methods of the interface cables, see "

Connecting an Ethernet 

interface cable

" and "

Connecting an optical interface cable

." 

 

Summary of Contents for SR6600 SPE-FWM

Page 1: ...H3C SR6600 SR6600 X Routers Interface Module Guide Hangzhou H3C Technologies Co Ltd http www h3c com Document version 6W106 20150618...

Page 2: ...gine SecPath SecCenter SecBlade Comware ITCMM and HUASAN are trademarks of Hangzhou H3C Technologies Co Ltd All other trademarks that may be mentioned in this manual are the property of their respecti...

Page 3: ...MIM 1CE3 RT MIM 1CE3 V2 H3 36 MIM 1CT3 RT MIM 1CT3 V2 H3 37 MIM 2SAE RT MIM 2SAE H3 MIM 4SAE RT MIM 4SAE H3 MIM 8SAE RT MIM 8SAE H3 39 SAPs 42 SAP 48GBE RT SAP 48GBE H3 42 SAP 24GBP RT SAP 24GBP H3 4...

Page 4: ...ii Interface module SAP and transceiver module compatibility matrix 73 Index 76...

Page 5: ...uter to communicate with a LAN It provides eight RJ 45 ports each of which supports the Layer 3 routing function and has a bi color status LED The HIM 8FE has the following features The transmission d...

Page 6: ...face MDI standard is typically used on the Ethernet interface of network adapters the medium dependent interface crossover MDI X standard is typically used on hubs or LAN switches Interface cables The...

Page 7: ...ort 3 GE port status LED 4 Ejector lever LEDs Table 3 LED description LED status Description Off No link is present or the cable is faulty Steady green A 1000 Mbps link is present Flashing green Data...

Page 8: ...gotiation mode When operating in forced mode an Ethernet copper port does not support auto MDI MDI X When operating in auto negotiation mode an Ethernet copper port supports auto MDI MDI X Interface c...

Page 9: ...screw 2 SFP port 3 SFP port status LED 4 Ejector lever LEDs Table 5 LED description LED status Description Off No link is present Steady green A 1000 Mbps link is present Flashing green The interface...

Page 10: ...ilable for the HIM 4GBP HIM 8GBP 100 Mbps fiber SFP transceiver modules 1000 Mbps fiber SFP transceiver modules 100 1000 Mbps fiber SFP transceiver modules 10 100 1000 Mbps copper SFP transceiver modu...

Page 11: ...K ACT LED Table 7 LED description LED status Description Off No link is present Steady green A link is present but no data is being received or transmitted Flashing green The XFP port is receiving or...

Page 12: ...o the processor through a 10 Gbps high speed bus Each CPOS interface can be channelized into 63 E1s or 84 T1s and it can be channelized into 512 DS0s Receives multiplexed E1 T1 circuits on a pair of f...

Page 13: ...ort carrier signal LED LINK ACT 2 SFP port loopback alarm LED LP AL 3 SFP port 4 Captive screw 5 Ejector lever LEDs Table 9 LED description LED Status Description LINK ACT Green Off No link is present...

Page 14: ...tion of a HIM CL1P HIM CL2P interface cable see Connecting an optical interface cable HIM CLS1P RT HIM CLS1P H3 HIM CLS2P RT HIM CLS2P H3 The HIM CLS1P and HIM CLS2P are high speed OC 3 STM 1 155 Mbps...

Page 15: ...ct The configuration of the operating mode takes effect for all the interfaces on the interface modules NOTE The HIM CLS1P HIM CLS2P does not support channelizing OC 3 STM 1 into DS1s or E1s Front pan...

Page 16: ...t power Type Short distance Medium distance Long distance Ultra long distance Min 19 0 dBm 15 0 dBm 5 0 dBm 5 0 dBm Max 14 0 dBm 8 0 dBm 0 dBm 0 dBm Receiving sensitivity 30 0 dBm 28 0 dBm 34 0 dBm 34...

Page 17: ...the interface module or reboot the device It is recommended to remove and insert the module to bring the configuration into effect The configuration of the operating mode takes effect for all the int...

Page 18: ...SFP port is receiving or sending data at 155 52 622 08 Mbps LP AL Yellow Off No loopback or alarm exists On The port is in loopback state Flashing There is a minimum of one alarm Interface specificati...

Page 19: ...49 71 miles Fiber type 9 125 m single mode 9 125 m single mode 9 125 m single mode Interface cables The HIM MSP2P HIM MSP4P must work with an SFP transceiver module and an optical fiber with LC type...

Page 20: ...ng or sending data at 2488 32 Mbps LP AL Yellow Off No loopback or alarm exists On The interface is in loopback state Flashing There is a minimum of one alarm Interface specifications Table 16 Interfa...

Page 21: ...PS1P interface cable see Connecting an optical interface cable HIM AL1P RT HIM AL1P H3 HIM AL2P RT HIM AL2P H3 The HIM AL1P and HIM AL2P are OC 3 STM 1 155 Mbps Asynchronous Transfer Mode ATM interfa...

Page 22: ...15 Front panel of HIM AL2P 1 Captive screw 2 Ejector lever 3 SFP port 4 SFP port carrier signal LED LINK ACT 5 SFP port loopback alarm LED LP AL LEDs Table 17 LED description LED Status Description L...

Page 23: ...24 86 miles 80 km 49 71 miles Fiber type 62 5 125 m multi mode 9 125 m single mode 9 125 m single mode 9 125 m single mode Interface cables The HIM AL1P HIM AL2P must work with an SFP transceiver mod...

Page 24: ...U On The node is in PASSTHRU MATESYNC Green Off The mate interface is not synchronized On The mate interface is synchronized WRAP Yellow Off No WRAP exists On WRAP occurs on this node Flashing 0 5 Hz...

Page 25: ...les Fiber type 9 125 m single mode 9 125 m single mode 9 125 m single mode 9 125 m single mode Interface cables Test optical power before choosing a transceiver module and optical fiber because an opt...

Page 26: ...nk is present Flashing green Data is being transmitted or received Steady yellow A loopback exists Flashing yellow An alarm has occurred Off No link is present Interface specifications Table 22 Ethern...

Page 27: ...dBm 7 0 dBm 9 0 dBm 10 0 dBm Central wavelength 1310 nm 1310 nm 1310 nm 1550 nm Max transmission distance 2 km 1 24 miles 15 km 9 32 miles 40 km 24 86 miles 80 km 49 71 miles Fiber type 62 5 125 m mul...

Page 28: ...Ejector lever 4 SFP port carrier signal LED LINK ACT LEDs Table 24 LED description LED Status Description SFP GE 1000Base X LINK ACT Green Off No link is present On A 1000 Mbps link is present Flashi...

Page 29: ...ctor type SFP Number of interfaces 0 to 8 Interface standards SONET STS 3 STS 12 SDH STM 1 STM 4 Interface speed 155 52 Mbps 622 08 Mbps OC 3 interface 155 52 Mbps Optical transmit power Type Short di...

Page 30: ...er modules The transceiver modules are optional Interface cables The HIM TS8P is used together with SFP transceiver modules and fibers with LC connectors For the appearance and connection of a HIM 4G4...

Page 31: ...40 km 24 86 miles 40 km 24 86 miles 70 km 43 50 miles Fiber type 62 5 125 m multi mode 9 125 m single mode 9 125 m single mode 9 125 m single mod e 9 125 m single mode Transmission rate 100 1000 Mbps...

Page 32: ...module provides 16 SFP ports These SFP ports support Layer 3 routing Front panel Figure 20 Front panel 1 Captive screw 2 SFP ports 3 SFP port LEDs 4 Ejector lever LED Table 29 SFP port LED descriptio...

Page 33: ...00 100 Mbps fiber SFP transceiver modules 10 100 1000 Mbps copper SFP transceiver modules 10 100 1000 Mbps autosensing is supported when the HIM 16GBP interface module uses this type of transceiver mo...

Page 34: ...d Interface specifications Table 32 SFP port specifications Item Specification Transceiver module type SFP Connector type LC Number of interfaces 2 Supported physical layer type LAN PHY 10GBASE R WAN...

Page 35: ...IM 2GBE H3 The MIM 2GBE is a 2 port 10 100 1000M Base T copper port RJ 45 module The MIM 2GBE is designed for router LAN communication Front panel Figure 22 Front panel 1 GE port 2 GE port link LED LI...

Page 36: ...s in auto negotiation mode An Ethernet copper port supports auto MDI MDI X in both forced or auto negotiation mode Interface cables A MIM 2GBE uses a category 5 straight through or crossover Ethernet...

Page 37: ...als are being received On Carrier signals are being received Flashing Data is being transmitted or received LP AL Yellow Off No loopback or alarms have occurred On The interface is in loopback state F...

Page 38: ...rface corresponds to one and only one serial interface which is automatically created without the need of additional configuration For the appearance and connection of a MIM 8E1 75 MIM 8E1 75 F interf...

Page 39: ...es supported Backup Terminal access service LEDs Table 38 LED description LED Status Description LINK ACT Green Off No carrier signals are being received On Carrier signals are being received Flashing...

Page 40: ...ives and processes high speed data streams over the E3 channel and provides access to E3 data streams In CE3 mode it provides the low speed access service at N 64 kbps where N is smaller than or equal...

Page 41: ...with one interface acting as the transmission end Tx and the other as the receiving end Rx The Tx and Rx interfaces operate in the 75 ohm unbalanced transmission mode and thereby need a pair of 75 ohm...

Page 42: ...Figure 28 Front panel 1 Carrier signal LED LINK ACT 2 TX interface 3 RX interface 4 Captive screw 5 Loopback alarm LED LP AL LEDs Table 41 LED description LED Status Description LINK ACT Off No carrie...

Page 43: ...e NOTE The MIM 1CT3 and MIM 1CE3 use the same type of E3 T3 cable The E3 T3 cable is an optional accessory for the MIM 1CE3 to be separately ordered if needed For the appearance and connection of an E...

Page 44: ...face 3 LEDs A LINK LED and an ACT LED are provided for each channel of the MIM 2SAE MIM 4SAE The MIM 8SAE provides only one LED for each channel Table 43 MIM 2SAE MIM 4SAE LED description LED Status D...

Page 45: ...e MIM 2SAE MIM 4SAE MIM 8SAE are synchronous asynchronous serial interface cables with DB 28 connectors Before connecting cables to the interfaces on the MIM 2SAE MIM 4SAE MIM 8SAE examine the line pr...

Page 46: ...n the LPU slots of the router SAP 48GBE RT SAP 48GBE H3 The SAP 48GBE is a 10Base T 100Base TX 1000Base T auto sensing Ethernet service module developed by H3C The SAP 48GBE provides 48 RJ 45 interfac...

Page 47: ...able or the SAP 48GBE has failed Slow flashing 1 Hz The SAP 48GBE is operating correctly Fast flashing 8 Hz System software image is being loaded in this case never power off the device or hot swap th...

Page 48: ...000 Mbps auto sensing optical Ethernet service module It provides 24 SFP ports all of which feature Layer 3 routing and high performance Layer 2 switching Each interface uses a bi color LED indicating...

Page 49: ...this case never power off the device or hot swap the SAP 24GBP otherwise the SAP 24GBP might be damaged SFP 0 to SFP 23 Yellow green Off No link is present or the cable is faulty Steady green A 1000...

Page 50: ...ovided by H3C only The device might be incompatible with other transceiver modules Interface cables When working with SFP transceiver modules the SAP 24GBP must use an optical fiber with LC type conne...

Page 51: ...defined for the SAP to prevent power module overloading You must use the theoretical max power consumption rather than the tested max power consumption to calculate the total power consumption for ma...

Page 52: ...m single mode fiber 9 125 m single mode fiber 9 125 m single mode fiber 9 125 m single mode fiber Max transmission distance 0 55 km 0 3418 miles 10 km 6 21 miles 40 km 24 86 miles 40 km 24 86 miles 70...

Page 53: ...EXP uses a run LED RUN to show the running status of the module Front panel Figure 35 Front panel 1 SFP ports 0 to 3 2 Status LED RUN 3 SFP port LEDs 4 Ejector lever 5 Captive screw Interface specific...

Page 54: ...pecifications Table 57 10G Ethernet port specifications Item Supported standard Protocol standard 802 3ae Connector type LC Transceiver module SFP Physical layer type supported 10GBASE R W Interface r...

Page 55: ...y type and size Default Two 2 GB DDR3 SDRAMs Maximum Four 2 GB DDR3 SDRAMs NVRAM 128 KB SFP ports 16 SFP ports 100 1000 Mbps auto sensing The following transceiver modules are available for the SFP po...

Page 56: ...orts GE16 to GE 19 yellow green Off No link is present Steady green A 1000 Mbps link is present Flashing green Data is being received or transmitted at 1000 Mbps Steady yellow A 10 100 Mbps link is pr...

Page 57: ...5 125 m multi mode 1250 Mbps 0 55 km 0 34 miles SFP GE LX SM1310 A 1310 nm LC 9 125 m single mode 1250 Mbps 10 km 6 21 miles SFP GE LH40 SM13 10 1310 nm LC 9 125 m single mode 1250 Mbps 40 km 24 86 mi...

Page 58: ...multi mode 9 125 m single mode 9 125 m single mode 9 125 m single mode Operating mode 10 Gpbs full duplex Table 65 Transceiver modules available for the SFP ports Model Central wavelength Connector O...

Page 59: ...each port to indicate the operating status of the port It also provides a RUN LED to indicate the operating status of the module Front panel Figure 37 Front panel 1 SFP ports GE0 to GE15 2 Combo inter...

Page 60: ...rts GE0 to GE15 yellow green Off No link is present Steady green A 1000 Mbps link is present Flashing green Data is being received or transmitted at 1000 Mbps Steady yellow A 100 Mbps link is present...

Page 61: ...00 Mbps full duplex Table 70 Transceiver modules available for the SFP ports Transceiver module model Central wavelength Connector Optical fiber Data rate Max transmission distance SFP GE SX MM85 0 A...

Page 62: ...transceiver modules provided by H3C only The router might be incompatible with other transceiver modules Interface cables Use the following cables for the SAP 28GE ports SFP port An SFP transceiver mo...

Page 63: ...les provide a transmission frequency of 1 MHz to 250 MHz and improve the performance on crosstalk and return loss A fine better return loss performance is extremely important for new generation full d...

Page 64: ...end of an Ethernet cable to an Ethernet port on the module and the other end to the Ethernet port on the peer device Because the Ethernet port of the module supports MDI MDIX auto sensing you can use...

Page 65: ...61 Figure 40 SFP transceiver module Figure 41 XFP transceiver module Figure 42 QSFP transceiver module Figure 43 LC type optical fiber connector 1 LC type optical fiber connector 2 Optical fiber 1 2...

Page 66: ...nd of one fiber cable into the Rx port of the router and the LC connector at the other end into the Tx port of the peer device Plug the LC connector at one end of another fiber cable into the Tx port...

Page 67: ...tter lightning protection when the cable is led outdoors For more information about lightning arrestor see the installation guide To connect the 4E1 8E1 splitter cable 1 Plug the DB 68 end of the 75 o...

Page 68: ...nector and connect the other end of the coaxial cable connector to the peer device through a 75 ohm E1 trunk cable Figure 47 Connecting the 4E1 8E1 splitter cable 2 3 Examine the LINK LED after connec...

Page 69: ...end of the cable to the Tx end of the peer device The coaxial cable connector and 75 ohm E1 trunk cable are optional accessories to be separately ordered if needed Connecting a T1 interface cable Appe...

Page 70: ...n If the LED is off a fault has occurred on the link In this case examine the link Connecting a CE3 CT3 interface cable Appearance of the E3 T3 cable Figure 50 E3 T3 cable NOTE H3C recommends that you...

Page 71: ...onnecting a serial interface cable Appearance of the serial interface cable Figure 51 V 24 DTE cable Figure 52 V 24 DCE cable Figure 53 V 35 DTE cable Figure 54 V 35 DCE cable A A Pos 28 Pos 1 X1 W X2...

Page 72: ...68 Figure 55 X 21 DTE cable Figure 56 X 21 DCE cable Figure 57 RS 449 DTE cable Figure 58 RS 449 DCE cable Figure 59 RS 530 DTE cable A Pos 1 Pos 15 A W B Pos 28 X1 Pos 1 B X2...

Page 73: ...the peer device and choose the synchronous serial interface cable of correct type 2 Plug the DB 28 end of the synchronous serial interface cable into the DB 28 interface of the SAE interface module 3...

Page 74: ...LPU and router compatibility matrix LPU SR6602 SR6604 SR6608 SR6616 SR6602 X1 X2 SR6604 X SR6608 X SR6616 X FIP 10 FIP 100 FIP 110 FIP 20 FIP 200 FIP 210 FIP 240 FIP 300 FIP 310 FIP 600 SAP 48GBE SAP...

Page 75: ...compatibility matrix MPU SR6602 SR6604 SR6608 SR6616 SR6602 X1 X2 SR6604 X SR6608 X SR6616 X RPE X1 RSE X1 RSE X2 MCP X1 MCP X2 Compatibility matrixes on Comware V7 LPU and router compatibility matri...

Page 76: ...MPU and router compatibility matrix Table 79 MPU and router compatibility matrix MPU SR6604 SR6608 SR6616 SR6602 X1 X 2 SR6604 X SR6608 X SR6616 X RPE X3 RSE X3 Interface module and FIP compatibility...

Page 77: ...2 Mbps fiber SFP transceiver module 1000 Mbps fiber SFP transceiver module 100 1000 Mbps fiber SFP transceiver module MIMs MIM 2GBE MIM 1POS MIM 8E1 MIM 8E1 F MIM 8T1 MIM 8T1 F MIM 1CE3 MIM 1CT3 MIM 1...

Page 78: ...8GBE SAP 24GBP SAP 48GBP SAP 4EXP SAP 20GE2XP SAP 28GE Table 82 Interface module and transceiver module compatibility matrix 2 Interface module SAP 10 100 1000 Mbps copper SFP transceiver module 2 5 G...

Page 79: ...FP transceiver module 10 Gbps fiber SFP transceiver module HIMs HIM 8FE HIM 4GBE HIM 8GBE HIM 4GBP HIM 8GBP HIM 1EXP HIM CL1P HIM CL2P HIM CLS1P HIM CLS2P HIM MSP2P HIM MSP4P HIM PS1P HIM AL1P HIM AL2...

Page 80: ...Connecting a serial interface cable 67 Connecting a T1 interface cable 65 Connecting an E1 interface cable 62 Connecting an Ethernet interface cable 59 Connecting an optical interface cable 60 H HIMs...

Reviews: