10-4
Figure10-5 Removing a FIP module
Replacing a MIC-X interface card
CAUTION:
You cannot install but can remove a MIC-X interface card when the device is operating.
To replace a MIC-X interface card:
1.
Verify that the FIP module is operating correctly.
The remove LED on the FIP module is steady green when the FIP module is operating correctly.
You can also use the
display device verbose
command to view the FIP module
operating status.
2.
Wear an ESD wrist strap. Make sure the wrist strap makes good skin contact and is reliably
grounded.
3.
Use a Phillips screwdriver to loosen the captive screws on the module.
4.
Open the two ejector levers of the interface card simultaneously.
5.
Pull the interface card slowly out of the slot along the guide rails.
6.
Place the removed interface card on an antistatic mat.
7.
Install a new MIC-X interface card.
CAUTION:
To install a new MIC-X interface card, first remove the FIP module from the device. For the
installation procedure, see "
Installing MIC-X interface cards
If you are not to install a new MIC-X interface card, install a filler panel in the slot.