10-1
10
Maintaining the device
Replacing a power supply
WARNING!
To avoid device damage or bodily injury, strictly follow the removal procedure in
to
remove a power supply.
Figure10-1 Power supply removal procedure
CAUTION:
For adequate heat dissipation and dust prevention, install a filler panel in a power supply slot if you
are not to install a new power supply in the slot after removing the old one.
To replace a power supply:
1.
Wear an ESD wrist strap. Make sure the wrist strap makes good skin contact and is reliably
grounded.
2.
Remove the power cord from the power supply.
3.
Pressing the latch on the power supply towards the handle direction, pull the power supply
slowly out of the slot, as shown in
4.
Place the removed power supply on an antistatic mat.
5.
Install a new power supply in the slot. For the installation procedure, see "
If you are no to install a new power supply, install a filler panel in the slot.
Figure10-2 Removing a power supply
Turn off the circuit
breaker
Disconnect the power
cord
Remove the power
supply