77
Figure 139 Selecting Initialization > Start FGI
NOTE:
•
Background Initialization (BGI) first initializes part of the RAID array space for data write
operations, and initializes the rest of the RAID array space in the background.
•
Full Ground Initialization (FGI) initializes the entire RAID array space. Data write operations
can be performed only when the initialization is complete.
3.
On the screen as shown in
, select
YES
and press
Enter
.
Figure 140 Confirming the operation
Erasing drives
CAUTION:
To avoid drive failure, do not perform other operations when erasing a physical drive.
This task allows you to erase physical and logical drives.
Erasing a physical drive
1.
On the
PD Mgmt
screen as shown in
, select the target drive and press
F2
.
Summary of Contents for UniServer B5700 G3
Page 35: ...19 Figure 29 Selecting the RAID volume to be deleted...
Page 116: ...56 Figure 96 Controller Configuration screen...
Page 220: ...61 Figure 109 Selecting Main Menu 2 Select Controller Management and press Enter...
Page 243: ...84 Figure 153 Confirming the operation...
Page 293: ...50 Figure 89 Clearing completion...
Page 382: ...21 Figure 27 Storage controller information...
Page 389: ...7 Figure 8 Identifying a storage controller 2...